background image

2.3 Safety instructions

1.Please

 

read

 

this

 

manual

 

carefully

 

before

 

installation.If

 

you

 

fail

 

to

 

install

 

according

 

to

 

the

 

instructions

 

in

 

this

 

manual,or

 

ignore

 

the

 

warnings

 

in

 

the

 

manual

 

and

 

the

 

equipment

 

is

 

damaged,our

 

company

 

reserves

 

the

 

right

 

not

 

to

 

guarantee

 

the

 

quality;

2.All operations and wiring should be finished by the professional electrical or mechanic-

al engineers;

3.During

 

installation,except

 

for

 

the

 

wiring

 

terminals,please

 

do

 

not

 

move

 

other

 

parts

 

inside

 

the

 

chassis;

4.All

 

electrical

 

installations

 

must

 

comply

 

with

 

local

 

electrical

 

safety

 

standards;

5.If

 

the

 

machine

 

needs

 

maintenance,please

 

contact

 

the

 

local

 

designated

 

system

 

installation

 

and

 

maintenance

 

personnel;

6.The

 

use

 

of

 

this

 

machine

 

for

 

grid

-

connected

 

power

 

generation

 

requires

 

permission

 

from

 

the

 

local

 

power

 

supply

 

department;

7.When

 

installing

 

photovoltaic

 

modules

 

during

 

the

 

day,use

 

opaque

 

materials

 

to

 

cover

 

the

 

photovoltaic

 

modules,otherwise

 

the

 

voltage

 

at

 

the

 

module

 

terminals

 

will

 

be

 

high

 

in

 

the

 

sun,which

 

may

 

cause

 

personal

 

danger

.

2.2 Qualification of skilled person 

This  grid-tied  inverter  system  operates  only  when  properly  connected  to  the  AC 

distribution network. Before connecting the MID TL3-X to the power distribution grid, 

contact the local power distribution grid company. This connection must be made only 

by  qualified  technical  personnel  to  connect,  and  only  after  receiving  appropriate 

approvals, as required by the local authority having jurisdiction.

Ø

Before installation, pleae check the unit to ensure that there is no   

transportation or handling damage, which may affect the 

insulation integrity or safety clearances; otherwise, it may cause 

safety hazards.

Ø

Follow the instructions in this manual to assemble the inverter. 

Note that select the suitable mounting location and comply with 

the specified requirements of cooling.

Ø

Unauthorized removal of necessary protections, improper use, 

incorrect installation and operation may lead to serious safety and 

shock hazards and/or equipment damage.

Ø

In order to minimize the possibility of shock hazards due to 

dangerous voltages, cover the entire solar array with dark colored 

materials before connecting the array to any equipment.

Ø

Grounding  the  PV  modules

the  MID  TL3-X  is  a  transformerless 

inverter.  which  means  there  is  no  galvanic  separation.  Do  not 

grounding the DC side of the MID TL3-X inverter. Only grounding 

the mounting frame of the photovoltaic module. Otherwise there 

will be an error message "PV ISO Low".

Ø

Comply  with  the  local  requirements  for  grounding  the  PV               

modules  and  the  PV  generator.  GROWATT  recommends 

connecting the generator frame and other electrically conductive 

surfaces  in  a  manner  which  ensures  continuous  conduction  with 

ground  in  order  to  have  optimal  protection  of  the  system  and 

personnel.

WARNING

CAUTION

2.3.1

 Assembly Warnings

2.3.2 Electrical Connection Warnings

Ÿ

Do not open the inverter except the wire box by qualified persons.

Ÿ

Electrical installation, repairs and conversions may only be carried 
out by electrically qualified persons.

Ÿ

Forbid live line work

.

Ø

Danger to life due to high voltages in the inverter

Ø

Persons with limited physical or mental abilities may only work 

with the Growatt inverter following proper instruction and under 

constant supervision. Must keep the Growatt inverter away from 

children.

Ÿ

There is residual voltage in the inverter after the device shutdown. 

The inverter need to take 20 minutes to discharge for safety.

Ø

The components in the inverter are live. Touching live components 

can result in serious injury or death.

DANGER

Ø

Make all electrical connections (e.g. conductor termination, 

fuses, PE connection, etc.) in accordance with prevailing 

regulations. When using the inverter to provide the power, 

adhere to all prevailing safety regulations to minimize risk of 

accidents.

Ø

Systems  with  inverters  typically  require  additional  control  (e.g., 

switches,  disconnects)  or  protective  devices  (e.g.,  fusing  circuit 
breakers) depending upon the prevailing safety rules.

WARNING

5

6

Summary of Contents for MID 17KTL3-X1

Page 1: ...henzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China 86 755 2747 1942 www ginverter com www ginverter com T E W service ginverter com service ginverter com 86 755 27...

Page 2: ...cation of skilled person 2 3 Safety instruction 4 Unpacking inspection 5 Installation 5 1 Basic installation requirements 5 2 Mounting wall mount 5 3 Installing the inverter 6 1 Security 6 2 AC side w...

Page 3: ...nty 15 Decommissioning 17 Specification 16 EU declaration of conformity 18 EU declaration of conformity 9 1 Boot display 9 2 OLED display wake up 9 3 Function setting 12 1 Start the inverter 12 2 Shut...

Page 4: ...ted to the Growatt device or cause personal injury 1 3 2 Markings on this product CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE i...

Page 5: ...nverter and other communication products to communicate with each other The wireless communication device is not standard Require to order extral if you need it Safety 2 2 1 Product description and fe...

Page 6: ...e incorrect installation and operation may lead to serious safety and shock hazards and or equipment damage In order to minimize the possibility of shock hazards due to dangerous voltages cover the en...

Page 7: ...ugh charge to create a shock hazard In order to minimize the occurrence of this situation observe all corresponding safety symbols and marks in this manual Under special circumstances the inverter may...

Page 8: ...k whether the outer package is damaged After unpacking please check whether the appearance of the inverter is damaged or lack of accessories If there is damage or missing parts please contact the deal...

Page 9: ...y of the installation environment should be between 0 and 90 The ambient temperature around the inverter should be between 25 C 60 C The inverter can be mounted on a plane that is tilted vertically or...

Page 10: ...wall for power or other piping before opening the hole in the wall Danger Secure the wall mount as shown do not let the screws flush with the wall instead expose 2 to 4 mm 5 3 Installing the inverter...

Page 11: ...gle core wire at the output terminal of the inverter It is forbidden to use aluminum wires as output cables Please ensure that the output cable is well connected before turning on the inverter Ignorin...

Page 12: ...witch Measure the voltage and frequency of the public grid voltage AC 230V frequency 50Hz The recommended specifications of the AC output switch are as follows Inverter model Switch specification MID...

Page 13: ...utput terminal before turning it on otherwise the inverter will be damaged If a stable non zero DC voltage is measured between the positive pole of the photovoltaic string and the ground it means that...

Page 14: ...ive connector Negative metal terminal 4 6mm 4 6mm Fig 6 7 Fig 6 8 Fig 6 9 1 2 3 4 B just for Vietnam models B just for Vietnam models A A Fig 6 10 Fig 6 11 Fig 6 12 Fig 6 13 2 Push the threaded sleeve...

Page 15: ...In this case the company does not carry out warranty and assumes any responsibility Photovoltaic panel Inverter Distribution Cabinet SPD Power grid Lightning protection device Grounding bar 1 2 3 4 To...

Page 16: ...the disconnection device Do not generate power Do not generate at more than 50 of rated power Do not generate at more than 75 of rated power and reduce the reactive power as far as possible Increase...

Page 17: ...n permanent shutdown The inverter has large electrical potential differences between its conductors Arc flashes can occur through air when high voltage current flows Do not work on the product during...

Page 18: ...uency return to normal the inverter will automatically connect to the grid 8 2 Failure mode The inverter controls the chip monitors and adjusts the state of the system in real time When the inverter m...

Page 19: ...er than the domestic legal requirements the inverter cannot be connected to the grid After obtaining the permission of the local power operator the user can choose other voltage levels according to th...

Page 20: ...0 2 USB A The inverter side The inverter side The inverter side The inverter side Unistall up Install USB A port is mainly used to connect monitoring module or firmware update We can connect the exter...

Page 21: ...ct terminal abnormal 1 Check the string terminal wiring after shutdown 2 If the fault message still exists contact the manufacturer Warning 202 DC lightning protection device alarm 1 Check the DC ligh...

Page 22: ...manufacturer Warning 305 Reverse connection of current transformer 1 Check whether the current transformer is connected reversely 2 If the fault message still exists contact the manufacturer Warning 3...

Page 23: ...line 2 If the fault information still exists contact the manufacturer Error 308 Pairing timeout 1 The pairing of the machine and the current transformer is overtime re pair 2 If the fault information...

Page 24: ...ttery reverse connection protection tube 1 Restart the machine 2 If the fault information still exists ontact the manufacturer Error 424 Battery voltage sampling is inconsistent 1 Restart the machine...

Page 25: ...voltage 1100V Start voltage 250V Nominal voltage 600V MPP voltage range 200 1000V No of MPP trackers 3 No of PV strings per MPP trackers 2 2 2 2 2 2 2 2 2 2 2 2 Max input current per MPP trackers 26A...

Page 26: ...RS485 YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 30KTL3 X MID 33KTL3 X MID 36KTL3 X MID 40KTL3 X Input data DC Max recommended PV power for module STC 45000W 49500W 54000W 60000W Max DC volt...

Page 27: ...5 YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 17KTL3 X1 MID 20KTL3 X1 MID 22KTL3 X1 MID 25KTL3 X1 Input data DC Max recommended PV power for module STC 25500W 30000W 33000W 375000W Max DC vol...

Page 28: ...YES WIFI GPRS 4G RF LAN OPT Model Specifications MID 30KTL3 X MID 33KTL3 X MID 36KTL3 X MID 40KTL3 X Input data DC Max recommended PV power for module STC 45000W 49500W 54000W 60000W Max DC voltage 11...

Page 29: ...aces Display OLED LED USB RS485 YES WIFI GPRS 4G RF LAN OPT 17 2 Torque Shell cover screw 12kgf cm AC terminal block 14kgf cm AC waterproof cover fixing screw 4kgf cm Security screws on the wall mount...

Page 30: ...act the Growatt New Energy Service Hotline We need the following information to provide you with the necessary help Inverter type Inverter serial number Inverter error message code Inverter OLED displ...