14.1 Specification

14 Technical Data 

7000TL-X

E

8000TL-X

E

7000TL-X*

Input data(DC)
Max. recommended PV 
power(for module STC)

11.2k

11.2k

12k

Max. DC voltage

600V

Start voltage

100V

Min. operating voltag

e

60V

Nominal voltage

360V

MPP voltage range

60-550

No. of MPP trackers

2

2

3

No. of PV strings per MPP 
trackers

1/2

1/2

1/1/1

Max. input current per MPP 
trackers

13.5/27A

13.5/27A

13.5/13.5/13.5A

Max. short-circuit current 
per MPP trackers

16.9/33.8A

16.9/33.8A

16.9/16.9/16.9A

Output data(AC)

Rated output power

7000W

8000W

7000W

Rated apparent power

7000VA

8000VA

7000VA

Max. apparent power

7000VA

8000VA

7000VA

Nominal AC 

voltage/range**

230/160~300V

AC grid frequency/range**

50-60Hz/44-55Hz;54-65Hz

Rated output current

30.4A

34.8A

30.4A

Max. output current

33.5A

38.3A

33.5A

Max output overload 
protection

50A

Max. inrush current
(Peak value/duration time)

<10A/5ms

Max. output fault current

(Peak value/duration time)

<108A/10us

Max. inverter backfeed 

current to PV array

0A

Power factor(@nominal 

power)

>0.99

Adjustable power factor

0.8leading…0.8lagging

THDi

<3%

AC grid connection type

Single phase

Overvoltage category

PV:II AC:III Others:I

Model

Specifications

Efficiency

Max. efficiency

98.1%

Euro-eta

97.3%

Protection devices
DC reverse-polarity 

protection

Integrated

DC switch

Integrated

DC Surge protection

Type II

AFCI

Optional

Insulation resistance 

monitoring

Integrated

AC surge protection

Type III

AC short-circuit protection

Integrated

Ground fault monitoring

Integrated

Grid monitoring

Integrated

Anti-islanding protection

Integrated

(

Active Frequency Drift)

Residual-current 
monitoring unit

Integrated

General data
Dimensions (W / H / D) in 
mm

425/387/180

Weight

18.2kg

Operating temperature 

range

–25 °C ... +60 °C

Noise emission (typical)

 25 dB(A)

Altitude

4000m

Internal consumption at 

night***

<1W

Topology

Non-isolated

Cooling

Natural convection

Protection degree

IP66

Relative humidity

0~100%

DC connection

H4/MC4(Optional)

AC connection

Cable gland +OT terminal

Interfaces
Display

OLED+LED

RS485/USB

Integrated

WIFI/GPRS/4G/LAN/RF

Optional

Warranty:5/10 years

Yes/ Optional

Summary of Contents for MIN 10000TL-X

Page 1: ...gy Co Ltd 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an District Shenzhen China GR UM A 0 229 1 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E...

Page 2: ...on of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in this...

Page 3: ...ication 14 2 DC connector and Isolator info 14 3 Torque 14 4 Accessories 6 Electrical connection 13 Decommissioning 7 Commissioning 14 Technical Data 7 1 Start the inverter 7 2 General setting 7 3 Adv...

Page 4: ...he Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model MIN 7000 TL X X E MIN 8000 TL X X E MIN 90...

Page 5: ...les Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with this MIN TL X single phase...

Page 6: ...al voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or death DANGER WARNING Ensure all co...

Page 7: ...nverter status LED color LED status Standby Green 0 5s on and 2s off Normal Green Solid Fault Red Solid Warning Green 0 5s on 0 5s off 0 5s on 2s off Programming Yellow 1s on and 1s off A C B D E F H...

Page 8: ...34 8A 0 8leading 0 8lagging 0 8leading 0 8lagging IP 66 IP 66 with derating above 45 C 113 F 25 60 13 140 F 25 60 13 140 F with derating above 45 C 113 F Model Height H Width W Depth D Weight MIN 00...

Page 9: ...he complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no user serviceable parts Refer serv...

Page 10: ...ut of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near television antenna or any other antennas and antenna cables Inverter requires...

Page 11: ...leave 2 to 4mm exposed Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wal...

Page 12: ...safely disconnected under load NOTE The inverter has the function of detecting residual current and protecting the inverter against residual current you must choose a Type A RCD breaker with the rati...

Page 13: ...ndard 62109 you must install the protective conductor on the AC terminal with a conductor cross section of at least 10 mm Cu Or Install a second protective conductor on the earth terminal with the sam...

Page 14: ...PV plant The Max open circuit voltage which can occur at solar panels temperature of 15 must not exceed the Max input voltage of the inverter WARNING WARNING Improper operation during the wiring proce...

Page 15: ...ed sleeve to connection terminal until both are locked tightly on Uninstall signal connector Step 1 Press the fasteners and pull it out from the inverter NC No Definition 1 2 3 4 12V COM RS 485A1 RS 4...

Page 16: ...40mA The CT Model is ESC16 32 ECHUN CTF16 2K5 32 Shenke The primary aperture is 10mm output cable length is 5m The arrow on the CT must pointing towards the inverter The detailed information about the...

Page 17: ...nvalid Information CAUTION 6 8 1 16Pin socket pin assignment COM Socket Pin No Assignment for inverters capable of discharging both charging and 9 10 11 12 13 14 DRM 5 DRM 6 DRM 7 DRM 8 RefGen Com DRM...

Page 18: ...es that newly installed PV systems attached to a building must be fitted with a means of detecting and disconnecting serial electric arcs AFCI on the PV side 6 9 2 Danger information Danger of fire fr...

Page 19: ...the inverter 7 1 1 Touch control 7 1 2 Country Area and Region setting Touch Single touch Double touch Three touch Hold 5s Description Switch display or Number 1 Enter Previous menu Confirm country se...

Page 20: ...tection settings 7 1 3 Enabling Disabling Power Quality Response Modes PQRM Information PQRM setting When the Region setting is completed the inverter will operate under default mode different from re...

Page 21: ...er 1 Double touch to confirm you setting Hold 5s recover defaut value Set Date 2018 12 14 Set Time 12 30 30 Set Date 2018 12 14 Set Date 2018 12 14 Set Time 12 30 30 Set Time 12 30 30 Set OK Set OK Se...

Page 22: ...to switch display or make the number 1 Double touch to confirm you setting Control type SW stands for enabling software limit control function HW stands for enabling hardware limit control function B...

Page 23: ...cause all configured parameters except the current date time and model parameters will be restored to their factory defaults Reset factory NO YES Set OK Set parameter General Advanced Password 7 3 4 A...

Page 24: ...inverter will start automatically when the input voltage is higher than 60 V 8 1 Start Up the inverter 8 2 Shut down the Inverter 9 1 Checking Heat Dissipation 9 2 Cleaning the Inverter Turn off the...

Page 25: ...ation of your inverter please read through the following information to correct the problem 11 1 Error Messages displayed on OLED An error message will be displayed on the OLED screen when a fault occ...

Page 26: ...till exist contact Growatt Auto Test Failed Error 407 Auto test didn t pass PV Voltage High Error 202 The DC input voltage is exceeding the maximum tolerable value 1 Disconnect the DC switch immediate...

Page 27: ...still exist Contact Growatt Error 422 The data sampled by the DSP and redundant M3 is not the same 12 Manufacturer Warranty Please refer to the warranty card 13 Decommissioning 13 1 Dismantling the I...

Page 28: ...nverter backfeed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Othe...

Page 29: ...feed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Others I Efficie...

Page 30: ...able you will find the optional accessories for your product If required you can order these from GROWATT NEW ENERGY CO LTD or your dealer Shipped to a Growatt service centre for repair or repaired on...

Page 31: ...r type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment SHENZHEN GROWATT NEW ENERGY CO LTD 4 13 F Building A Sin...

Reviews: