Notes on this manual

1.1 Validity

1

2

1.2 Target Group

This  manual  is  for  qualified  personnel.  Qualified  personnel  have  received  training  and 

have  demonstrated  skills  and  knowledge  in  the  construction  and  operation  of  this 

device. Qualified Personnel are trained to deal with the dangers and hazards involved in 

installing electric devices.

1.3 Additional information

Find further information on special topics in the download area at www.ginverter.com

The manual and other documents must be stored in a convenient place and be available 

at all times. We assume no liability for any damage caused by failure to observe these 

instructions. For possible changes in this manual, GROWATT NEW ENERGY CO.,LTD 

accepts no responsibilities to inform the users.

1.4.2 

Markings on this product

1.4 

Symbols in this document

1.4.1 Symbols in this document

A warning describes a hazard to equipment or personnel. It calls attention to a procedure 

or practice, which, if not correctly performed or adhered to, could result in damage to or 

destruction of part or all of the Growatt equipment and/or other equipment connected 

to the Growatt equipment or personal injury.

This manual describes the assembly, installation, commissioning and maintenance of the 

following Growatt Inverter model:

MIN 7000 TL-X/X(E)

MIN 8000 TL-X/X(E)

MIN 9000 TL-X

MIN 10000 TL-X

This manual does not cover any details concerning equipment connected to the MIN TL-

X( e.g. PV modules). Information concerning the connected equipment is available from 

the manufacturer of the equipment.

NOTICE

 is used to address practices not related to personal injury.

Information

operation of the system.

 that you must read and know to ensure optimal 

NOTICE

Information

WARNING

DANGER

Symbol

description

DANGER

result in death or serious injury.

 indicates a hazardous situation which, if not avoided, will 

WARNING

could result in death or serious injury.

  indicates  a  hazardous  situation  which,  if  not  avoided, 

Symbol

Explanation

Electrical voltage!

Point of connection for grounding protection

Risk of burns

Alternating Current (AC)

Risk of fire or explosion

Direct Current (DC) 

Operation after 5 minutes

Read the manual

CE mark.

The inverter complies with the requirements of the applicable CE 

guidelines.

The inverter must not be disposed of with the household waste.

   Isolation Switch

CAUTION

CAUTION

  indicates  a  hazardous  situation  which,  if  not  avoided, 

could result in minor or moderate injury.

 

Summary of Contents for MIN 10000TL-X

Page 1: ...gy Co Ltd 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an District Shenzhen China GR UM A 0 229 1 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E...

Page 2: ...on of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in this...

Page 3: ...ication 14 2 DC connector and Isolator info 14 3 Torque 14 4 Accessories 6 Electrical connection 13 Decommissioning 7 Commissioning 14 Technical Data 7 1 Start the inverter 7 2 General setting 7 3 Adv...

Page 4: ...he Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model MIN 7000 TL X X E MIN 8000 TL X X E MIN 90...

Page 5: ...les Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with this MIN TL X single phase...

Page 6: ...al voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or death DANGER WARNING Ensure all co...

Page 7: ...nverter status LED color LED status Standby Green 0 5s on and 2s off Normal Green Solid Fault Red Solid Warning Green 0 5s on 0 5s off 0 5s on 2s off Programming Yellow 1s on and 1s off A C B D E F H...

Page 8: ...34 8A 0 8leading 0 8lagging 0 8leading 0 8lagging IP 66 IP 66 with derating above 45 C 113 F 25 60 13 140 F 25 60 13 140 F with derating above 45 C 113 F Model Height H Width W Depth D Weight MIN 00...

Page 9: ...he complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no user serviceable parts Refer serv...

Page 10: ...ut of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near television antenna or any other antennas and antenna cables Inverter requires...

Page 11: ...leave 2 to 4mm exposed Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wal...

Page 12: ...safely disconnected under load NOTE The inverter has the function of detecting residual current and protecting the inverter against residual current you must choose a Type A RCD breaker with the rati...

Page 13: ...ndard 62109 you must install the protective conductor on the AC terminal with a conductor cross section of at least 10 mm Cu Or Install a second protective conductor on the earth terminal with the sam...

Page 14: ...PV plant The Max open circuit voltage which can occur at solar panels temperature of 15 must not exceed the Max input voltage of the inverter WARNING WARNING Improper operation during the wiring proce...

Page 15: ...ed sleeve to connection terminal until both are locked tightly on Uninstall signal connector Step 1 Press the fasteners and pull it out from the inverter NC No Definition 1 2 3 4 12V COM RS 485A1 RS 4...

Page 16: ...40mA The CT Model is ESC16 32 ECHUN CTF16 2K5 32 Shenke The primary aperture is 10mm output cable length is 5m The arrow on the CT must pointing towards the inverter The detailed information about the...

Page 17: ...nvalid Information CAUTION 6 8 1 16Pin socket pin assignment COM Socket Pin No Assignment for inverters capable of discharging both charging and 9 10 11 12 13 14 DRM 5 DRM 6 DRM 7 DRM 8 RefGen Com DRM...

Page 18: ...es that newly installed PV systems attached to a building must be fitted with a means of detecting and disconnecting serial electric arcs AFCI on the PV side 6 9 2 Danger information Danger of fire fr...

Page 19: ...the inverter 7 1 1 Touch control 7 1 2 Country Area and Region setting Touch Single touch Double touch Three touch Hold 5s Description Switch display or Number 1 Enter Previous menu Confirm country se...

Page 20: ...tection settings 7 1 3 Enabling Disabling Power Quality Response Modes PQRM Information PQRM setting When the Region setting is completed the inverter will operate under default mode different from re...

Page 21: ...er 1 Double touch to confirm you setting Hold 5s recover defaut value Set Date 2018 12 14 Set Time 12 30 30 Set Date 2018 12 14 Set Date 2018 12 14 Set Time 12 30 30 Set Time 12 30 30 Set OK Set OK Se...

Page 22: ...to switch display or make the number 1 Double touch to confirm you setting Control type SW stands for enabling software limit control function HW stands for enabling hardware limit control function B...

Page 23: ...cause all configured parameters except the current date time and model parameters will be restored to their factory defaults Reset factory NO YES Set OK Set parameter General Advanced Password 7 3 4 A...

Page 24: ...inverter will start automatically when the input voltage is higher than 60 V 8 1 Start Up the inverter 8 2 Shut down the Inverter 9 1 Checking Heat Dissipation 9 2 Cleaning the Inverter Turn off the...

Page 25: ...ation of your inverter please read through the following information to correct the problem 11 1 Error Messages displayed on OLED An error message will be displayed on the OLED screen when a fault occ...

Page 26: ...till exist contact Growatt Auto Test Failed Error 407 Auto test didn t pass PV Voltage High Error 202 The DC input voltage is exceeding the maximum tolerable value 1 Disconnect the DC switch immediate...

Page 27: ...still exist Contact Growatt Error 422 The data sampled by the DSP and redundant M3 is not the same 12 Manufacturer Warranty Please refer to the warranty card 13 Decommissioning 13 1 Dismantling the I...

Page 28: ...nverter backfeed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Othe...

Page 29: ...feed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Others I Efficie...

Page 30: ...able you will find the optional accessories for your product If required you can order these from GROWATT NEW ENERGY CO LTD or your dealer Shipped to a Growatt service centre for repair or repaired on...

Page 31: ...r type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment SHENZHEN GROWATT NEW ENERGY CO LTD 4 13 F Building A Sin...

Reviews: