1.5 Glossary

4

3

AC

Abbreviation for "Alternating Current"

DC

Abbreviation for "Direct Current"

Energy

Energy is measured in Wh (watt hours), kWh (kilowatt hours) or MWh (megawatt hours). 
The  energy  is  the  power  calculated  over  time.  For  example,  your  inverter  operates  at  a 
constant power of 4600 W for half an hour and then at a constant power of 2300 W for 
another half an hour, it has fed 3450Wh of energy into the power distribution grid within 
that hour.

Power

Power  is  measured  in  W  (watts),  kW  (kilowatts)  or  MW  (megawatts).  Power  is  an 
instantaneous  value.  It  displays  the  power  your  inverter  is  currently  feeding  into  the 
power distribution grid.

Power rate

Power rate is the radio of current power feeding into the power distribution grid and the 
maximum power of the inverter that can feed into the power distribution grid.

Power factor

Power factor is the ratio of true power or watts to apparent power or volt amps. They are 
identical  only  when  current  and  voltage  are  in  phase  than  the  power  factor  is  1.0.  The 
power in an ac circuit is very seldom equal to the direct product of the volts and amperes. 
In order to find the power of a single phase ac circuit the product of volts and amperes 
must be multiplied by the power factor.

PV

Abbreviation for photovoltaic.

Wireless communication

The external wireless communication technology is a radio technology that allows the 

inverter and other communication products to communicate with each other. The 

external wireless communication does not require line of sight between the devices and 

it is selective purchasing.

2

 

Safety

2.1 Intended Use

2.2 Qualification of skilled person 

2.3 Safety instruction 

The  unit  converts  the  DC  current  generated  by  the  photovoltaic  (PV)  modules  to  grid-
compliant  alternating  current  and  performs  single-phase  feed-in  into  the  electricity 
grid.MIN  7000-10000TL-X  inverters  are  built  according  to  all  required  safety  rules. 
Nevertheless, improper use may cause lethal hazards for the operator or third parties, or 
may result in damage to the units and other property.

Principle of a PV plant with this MIN TL-X single-phase inverter

Position                                                            Description

A

B

C

D

E

F

PV modules

DC load circuit breaker

AC load circuit breaker

Energy meter

Utility grid

Inverter

The  inverter  may  only  be  operated  with  a  permanent  connection  to  the  public  power 

grid.  The  inverter  is  not  intended  for  mobile  use.  Any  other  or  additional  use  is  not 

considered the intended use. The manufacturer/supplier is not liable for damage caused 

by such unintended use. Damage caused by such unintended use is at the sole risk of the 

operator.

PV modules Capacitive Discharge Currents

PV  modules  with  large  capacities  relative  to  earth,  such  as  thin-film  PV  modules  with 

cells on a metallic substrate, may only be used if their coupling capacity does not exceed 

1uF. During feed-in operation, a leakage current flows from the cells to earth, the size of 

which depends on the manner in which the PV modules are installed (e.g. foil on metal 

roof) and on the weather (rain, snow). This "normal" leakage current may not exceed 

50mA due to the fact that the inverter would otherwise automatically disconnect from 

the electricity grid as a protective measure.

This  grid-tied  inverter  system  operates  only  when  properly  connected  to  the  AC 

distribution  network.  Before  connecting  the  MIN  TL-X  to  the  power  distribution  grid, 

contact the local power distribution grid company. This connection must be made only 

by  qualified  technical  personnel  to  connect,  and  only  after  receiving  appropriate 

approvals, as required by the local authority having jurisdiction.

The  MIN  TL-X  Inverters  is  designed  and  tested  according  to  international  safety 
requirements

IEC62109-1,CE,VDE0126-1-1,  AS4777,etc

;  however,  certain  safety 

precautions  must  be  observed  when  installing  and  operating  this  inverter.  Read  and 
follow  all  instructions,  cautions  and  warnings  in  this  installation  manual.  If  questions 
arise, please contact Growatt's technical services at +86 (0)755 2747 1942.

A

B

C

D

E

F

Summary of Contents for MIN 10000TL-X

Page 1: ...gy Co Ltd 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an District Shenzhen China GR UM A 0 229 1 86 0755 2747 1942 86 0755 2747 1942 www ginverter com www ginverter com T E...

Page 2: ...on of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in this...

Page 3: ...ication 14 2 DC connector and Isolator info 14 3 Torque 14 4 Accessories 6 Electrical connection 13 Decommissioning 7 Commissioning 14 Technical Data 7 1 Start the inverter 7 2 General setting 7 3 Adv...

Page 4: ...he Growatt equipment or personal injury This manual describes the assembly installation commissioning and maintenance of the following Growatt Inverter model MIN 7000 TL X X E MIN 8000 TL X X E MIN 90...

Page 5: ...les Nevertheless improper use may cause lethal hazards for the operator or third parties or may result in damage to the units and other property Principle of a PV plant with this MIN TL X single phase...

Page 6: ...al voltage in the inverter The inverter takes 20 minutes to ischarge The components in the inverter are live Touching live components can result in serious injury or death DANGER WARNING Ensure all co...

Page 7: ...nverter status LED color LED status Standby Green 0 5s on and 2s off Normal Green Solid Fault Red Solid Warning Green 0 5s on 0 5s off 0 5s on 2s off Programming Yellow 1s on and 1s off A C B D E F H...

Page 8: ...34 8A 0 8leading 0 8lagging 0 8leading 0 8lagging IP 66 IP 66 with derating above 45 C 113 F 25 60 13 140 F 25 60 13 140 F with derating above 45 C 113 F Model Height H Width W Depth D Weight MIN 00...

Page 9: ...he complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no user serviceable parts Refer serv...

Page 10: ...ut of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near television antenna or any other antennas and antenna cables Inverter requires...

Page 11: ...leave 2 to 4mm exposed Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wal...

Page 12: ...safely disconnected under load NOTE The inverter has the function of detecting residual current and protecting the inverter against residual current you must choose a Type A RCD breaker with the rati...

Page 13: ...ndard 62109 you must install the protective conductor on the AC terminal with a conductor cross section of at least 10 mm Cu Or Install a second protective conductor on the earth terminal with the sam...

Page 14: ...PV plant The Max open circuit voltage which can occur at solar panels temperature of 15 must not exceed the Max input voltage of the inverter WARNING WARNING Improper operation during the wiring proce...

Page 15: ...ed sleeve to connection terminal until both are locked tightly on Uninstall signal connector Step 1 Press the fasteners and pull it out from the inverter NC No Definition 1 2 3 4 12V COM RS 485A1 RS 4...

Page 16: ...40mA The CT Model is ESC16 32 ECHUN CTF16 2K5 32 Shenke The primary aperture is 10mm output cable length is 5m The arrow on the CT must pointing towards the inverter The detailed information about the...

Page 17: ...nvalid Information CAUTION 6 8 1 16Pin socket pin assignment COM Socket Pin No Assignment for inverters capable of discharging both charging and 9 10 11 12 13 14 DRM 5 DRM 6 DRM 7 DRM 8 RefGen Com DRM...

Page 18: ...es that newly installed PV systems attached to a building must be fitted with a means of detecting and disconnecting serial electric arcs AFCI on the PV side 6 9 2 Danger information Danger of fire fr...

Page 19: ...the inverter 7 1 1 Touch control 7 1 2 Country Area and Region setting Touch Single touch Double touch Three touch Hold 5s Description Switch display or Number 1 Enter Previous menu Confirm country se...

Page 20: ...tection settings 7 1 3 Enabling Disabling Power Quality Response Modes PQRM Information PQRM setting When the Region setting is completed the inverter will operate under default mode different from re...

Page 21: ...er 1 Double touch to confirm you setting Hold 5s recover defaut value Set Date 2018 12 14 Set Time 12 30 30 Set Date 2018 12 14 Set Date 2018 12 14 Set Time 12 30 30 Set Time 12 30 30 Set OK Set OK Se...

Page 22: ...to switch display or make the number 1 Double touch to confirm you setting Control type SW stands for enabling software limit control function HW stands for enabling hardware limit control function B...

Page 23: ...cause all configured parameters except the current date time and model parameters will be restored to their factory defaults Reset factory NO YES Set OK Set parameter General Advanced Password 7 3 4 A...

Page 24: ...inverter will start automatically when the input voltage is higher than 60 V 8 1 Start Up the inverter 8 2 Shut down the Inverter 9 1 Checking Heat Dissipation 9 2 Cleaning the Inverter Turn off the...

Page 25: ...ation of your inverter please read through the following information to correct the problem 11 1 Error Messages displayed on OLED An error message will be displayed on the OLED screen when a fault occ...

Page 26: ...till exist contact Growatt Auto Test Failed Error 407 Auto test didn t pass PV Voltage High Error 202 The DC input voltage is exceeding the maximum tolerable value 1 Disconnect the DC switch immediate...

Page 27: ...still exist Contact Growatt Error 422 The data sampled by the DSP and redundant M3 is not the same 12 Manufacturer Warranty Please refer to the warranty card 13 Decommissioning 13 1 Dismantling the I...

Page 28: ...nverter backfeed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Othe...

Page 29: ...feed current to PV array 0A Power factor nominal power 0 99 Adjustable power factor 0 8leading 0 8lagging THDi 3 AC grid connection type Single phase Overvoltage category PV II AC III Others I Efficie...

Page 30: ...able you will find the optional accessories for your product If required you can order these from GROWATT NEW ENERGY CO LTD or your dealer Shipped to a Growatt service centre for repair or repaired on...

Page 31: ...r type Serial number of the inverter Event number or display message of the inverter Type and number of PV modules connected Optional equipment SHENZHEN GROWATT NEW ENERGY CO LTD 4 13 F Building A Sin...

Reviews: