The position of export limitation Meter must between the Inverter & 
Load and gird.
Multiple inverter combination is not suitable in Australia.

The smart meter can be used only up to 2000m altitude.

Step 3 Push the threaded sleeve to connection terminal until both are locked tightly on 

 

the inverter.

Step 1 Press the fasteners and pull it out from the inverter.

Step 2 Insert the H type tool and pull it out from the socket.

6.6 Grounding the inverter

The inverter must be connected to the AC grounding conductor of the power 

distribution grid via the ground terminal (PE) . 

The inverter side

The inverter side

This  series  inverter  has  integrated  generation    limitation  control  and  export  limitation 

Functionality.The  generation  control  function  is  used  to  control  the  active  or  apparent 

power output levels of an inverter.The export limit control function for an inverter is used 

to  control  the  generation  from  an  inverter  to  manage  the  export  power  level  from  an 

electrical installation to the grid. To use this function, you can connect smart meter.The 

smart  meter  model  is  Eastron  SDM120CT-M(40mA).The  primary  aperture  is 

10mm,output  cable  length  is  5m.The  arrow  on  the  CT  must  pointing  towards  the 

inverter.The  detailed  information  about  the  Meter,please  refer  to  Annex  -Eastron 

SDM120CT-M(40mA) user manual.

A

B

C

D

E

F

Manufacturer

Eastron

Type

SDM120CT-M(40mA)

General Specifications

Voltage AC (Un) 

Voltage Range 

Base Current (Ib) 

Power consumption 

230V

176~276V AC

0.1V AC

<2W/10VA

Frequency 

50/ 60Hz(±10%)

AC voltage withstand 

4KV for 1 minute

Impulse voltage withstand 

6KV-1.2uS waveform

Overcurrent withstand

20Imax for 0.5s

Pulse output 1 

1000imp/kWh (default)

Pulse output 2 

0.001(default)  /0.01/0.1/1  kWh/kVArh 

(configurable)

Display 
Max. Reading 

LCD with white backlit
999999kWh

Load

RS485

Summary of Contents for MIN 2500TL-XA

Page 1: ...IN 4600TL XA MIN 5000TL XA MIN 6000TL XA GR UM 257 A 00 Download Manual Growatt New Energy Shenzhen Growatt New Energy Co Ltd 4 13 F Building A Sino German Europe Industrial Park Hangcheng Ave Bao an...

Page 2: ...on of skilled person 2 3 Safety instruction 2 4 Assembly Warnings 2 5 Electrical Connection Warnings 2 6 Operation Warnings 1 1 Validity 1 2 Target Group 1 3 Additional information 1 4 Symbols in this...

Page 3: ...nnectors info 14 3 Torque 14 4 Accessories 6 Electrical connection 13 Decommissioning 7 Commissioning 14 Technical Data 7 1 Start the inverter 7 2 General setting 7 3 Advanced setting 7 4 Communicatio...

Page 4: ...es the assembly installation commissioning and maintenance of the following Growatt Inverter model MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA MIN 4200 TL XA MIN 4600 TL XA MIN 5000 TL XA MIN 6000 TL...

Page 5: ...r The external wireless communication does not require line of sight between the devices and it is selective purchasing Safety 2 The unit converts the DC current generated by the battery BAT to grid c...

Page 6: ...of accidents Systems with inverters typically require additional control e g switches disconnects or protective devices e g fusing circuit breakers depending upon the prevailing safety rules DANGER E...

Page 7: ...off 0 5s on 2S off programming Yellow 1s on and 1s off The type labels provide a unique identification of the inverter The type of product Device specific characteristics Certificates and approvals T...

Page 8: ...imensions and weight 10 9 Model Name MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA DC nominal input voltage 400V DC input voltage range 360 500V 360 500V 360 550V DC Max input output current 17A AC nom...

Page 9: ...regulations for the complete system All electrical installations shall be done in accordance with the local and national electrical codes Do not remove the casing Inverter contains no user serviceabl...

Page 10: ...oids forward and sideways tilt Be sure that the inverter is out of the children s reach Don t put any things on the inverter Do not cover the inverter Do not install the inverter near television anten...

Page 11: ...d leave 2 to 4mm exposed Falling equipment can cause serious or even fatal injury never mount the inverter on the bracket unless you are sure that the mounting frame is really firmly mounted on the wa...

Page 12: ...XA MIN 6000 TL XA The AC wiring step 1 Uninstall the parts of the AC connection plug from the accessory bag 2 Insert the stripped and bared cable through pressure screw seal ring threaded sleeve in s...

Page 13: ...then pull it out Wire suggestion length Conductor cross section Max cable length MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA 4 mm 12AWG 48m 40m 33m 5 2 mm 10AWG 60m 50m 42m Conductor cross section Ma...

Page 14: ...erable damage to the inverter Only qualified personnel can perform the wiring work WARNING WARNING 6 3 Connecting the second protective conductor In some installation countries a second protective con...

Page 15: ...um ion battery pack is not properly connected or the electrical disconnection will cause the equipment to work abnormally or even damage the equipment 6 5 Connecting signal cable This series inverter...

Page 16: ...ower output levels of an inverter The export limit control function for an inverter is used to control the generation from an inverter to manage the export power level from an electrical installation...

Page 17: ...RM6 DRM7 DRM8 are available Damage to the inverter due to moisture and dust penetration Make sure the cable gland has been tightened firmly If the cable gland are not mounted properly the inverter can...

Page 18: ...age the inverter External voltage of PCI PORT don t over 5V WARNING 6 8 1 2 Method of asserting demand response modes RRCR PCI Connector 6 8 2 1 8Pin socket pin assignment Pin Description Connect to R...

Page 19: ...ther region after 30s When inverter powered on OLED will light automatically Once the BAT power is sufficient OLED displays the following Press the touch key once a second to scroll through the differ...

Page 20: ...2019 04 18 Double touch Date Setting 20NN 04 18 Double touch Double touch Date Setting 20NN 04 18 Multiple single touch Date Setting 20NN NN 18 Double touch Multiple single touch Date Setting 20NN NN...

Page 21: ...e touch ExportLImit Rate 000 0 ExportLImit Rate 0N0 0 Double touch Multiple single touch ExportLImit Rate 0N0 0 ExportLImit Rate 0NN 0 Multiple single touch Set OK Double touch Double touch ExportLImi...

Page 22: ...Disable LoadFirst 00 01 Time1 Enable Multiple single touch Multiple single touch Multiple single touch Double touch Double touch Double touch Double touch Double touch Double touch Single touch Single...

Page 23: ...5A2 Connect Min ShineBus or third party monitoring equipment 7 BAT B Connect the BAT communi cation RS485B or CANL 4 RS485B2 Connect Min ShineBus or third party monitoring equipment 8 BAT A Connect th...

Page 24: ...issipation 9 2 Cleaning the Inverter 9 3 Checking the DC Disconnect If the inverter regularly reduces its output power due to high temperature please improve the heat dissipation condition Maybe you n...

Page 25: ...by system instead of inverter please check the items as instructed below before replacing inverter Error message Description Suggestion Residual I High Error 201 Leakage current too high Restart the...

Page 26: ...7 The data sampled by the DSP and redundant M3 is not the same 1 Restart inverter 2 I f problem still exist contact Growatt Error 420 GFCI fault 1 Restart inverter 2 I f problem still exist contact Gr...

Page 27: ...HDi 3 AC grid connection type Single phase L N PE AC overvoltage category Category III Model Specifications MIN 2500 TL XA MIN 3000 TL XA MIN 3600 TL XA MIN 4200 TL XA AC input quantities Nominal AC i...

Page 28: ...m continuous 17A DC output quantities Nominal DC output voltage 400V DC output voltage range 360 550V DC output current maximum continuous 17A Battery type Cobalt Free Lithium Iron Phosphate LFP AC ou...

Page 29: ...monitoring Integrated Anti islanding protection Integrated Active Frequency Drift Residual current monitoring unit Integrated General data Dimensions W H D in mm 375 350 160 Weight 9 1 kg Operating te...

Page 30: ...nfo 14 3 Torque BAT connectors VP D4B CHSM0B VP D4B CHSF0B AC connector VPAC06EP 3S SC 5 EN032 1128 1001 VPAC06EW 3P SC Enclosure lid screws 12kgf cm AC terminal 6kgf cm Signal terminal 4kgf cm M6 sok...

Reviews: