MIN
4600 TL-XA
MIN
5000 TL-XA
MIN
6000 TL-XA
AC input quantities
Nominal AC input voltage
230V
AC input voltage range
160-276V
AC input current(maximum
continuous)
20.9A
22.7A
27.2A
Inrush current
<
10A
Nominal frequency
50/60Hz
AC input frequency range
45-55Hz/55-65Hz
Efficiency
Max. efficiency
98.4%
98.4%
98.4%
Euro-eta
97.5%
97.5%
97.5%
Protection devices
DC reverse-polarity protection
Integrated
DC Surge protection class
Type II
Insulation resistance
monitoring
Integrated
AC surge protection class
Type III
AC short-circuit protection
Integrated
Ground fault monitoring
Integrated
Grid monitoring
Integrated
Anti-islanding protection
Integrated(Active Frequency Drift)
Residual-current monitoring
unit
Integrated
General data
Dimensions (W / H / D) in mm
375*350*160
Weight
9.1 kg
Operating temperature range
–25 °C ... +60 °C
Noise emission (typical)
<
25 dB(A)
Altitude
4000m
Internal consumption at night
<5W@storage mode
Topology
Non-isolated
Overvoltage category
AC:III BAT:II Others:I
Cooling
Natural convection
Ingress protection
IP65
Model
Specifications
MIN
4600 TL-XA
MIN
5000 TL-XA
MIN
6000 TL-XA
Pollution degree outside the
enclosure
3
Pollution degree inside the
enclosure
2
Relative humidity
0~100%
DC connection
VP-D4
AC connection
AC connector
Interfaces
Display
OLED+LED
RS485/USB
Integrated
WIFI/GPRS/4G/LAN/ RF
Optional
Warranty:5/10 years
Yes/ Optional
Model
Specifications