24
23
6.5.2
Connecting the Battery
DANGER
Danger to life due to lethal voltages!
Before connecting the Battery, ensure that it does not connect any
power supply. NEVER connect or disconnect the Battery.
Forbidden to reverse the positive and negative poles of the Battery
and the inverter.
WARNING
Improper operation during the wiring process can cause fatal
injury to operator or unrecoverable damage to the inverter. Only
qualified personnel can perform the wiring work.
Connection of BAT input terminal
4~6mm²
Cable
Positive metal
terminal
Positive connector
6.5
Connecting the Battery
6.5.1
Conditions for the Battery
The MIN TL-XH single-phase inverter has one independent Battery input : BAT+/BAT-
connecting to the output of the Battery.
Notice that the connectors are in paired (male and female connectors). The connectors for
the Battery and inverters are Helios H4-R/VP-D4 connectors;
4~6mm²
Cable
Negative metal
terminal
Negative connector