27
28
General Specifications
Voltage AC (Un)
Voltage Range
Base Current (Ib)
Power consumption
230V
176~276V AC
0.1V AC
<2W/10VA
Frequency
50/ 60Hz(±10%)
AC voltage withstand
4KV for 1 minute
Impulse voltage withstand
6KV-1.2uS waveform
Overcurrent withstand
20Imax for 0.5s
Pulse output 1
1000imp/kWh (default)
Pulse output 2
0.001(default) /0.01/0.1/1 kWh/kVArh
(configurable)
Display
Max. Reading
LCD with white backlit
999999kWh
Environment
Operating temperature
-25
℃
to +55
℃
Storage and transportation
temperature
-40
℃
to +70
℃
Reference temperature
23
℃
± 2
℃
Relative humidity
0 to 95%, non-condensing
Altitude
up to 2000m
Warm up time
3s
Installation category
CAT II
Mechanical Environment
M1
Electromagnetic environment
E2
Degree of pollution
2
Mechanics
Din rail dimensions
18x118x64 (WxHxD) DIN 43880
Mounting
DIN rail 35mm
Ingress protection
IP51 (indoor)
Material
self-extinguishing UL94V-0
The following table describes how we can connect EASTRON meter
(SDM120CT(40mA) to inverter:
Meter Pin NO.
Description
Meter Connection
1
CT-input
CT-P(White)
2
CT-N(Black or Blue)
3
N-in
Grid N
4
L-in
Grid L
9
RS485B
RS485B2 connect to inverter SYS COM Pin 8
10
RS485A
RS485A2 connect to inverter SYS COM Pin 7
Active power control with a Radio Ripple Control Receiver(RRCR).
6.9
Connecting the COM PORT
This series inverter has a 8 Pin COM PORT, this port has the function fo demand response modes,
for Australian mode, we can use the 8 Pin COM PORT as inverter DRED connection, for European
modes, we can use the 8 Pin COM PORT as Power Control Interface(PCI).
Information
DRMS application description
Only applicable to AS/NZS4777.2
DRM0, DRM1, DRM2, DRM3, DRM4, DRM5, DRM6, DRM7,
DRM8 are available.
CAUTION
Damage to the inverter due to moisture and dust penetration
Make sure the cable gland has been tightened firmly.
If the cable gland are not mounted properly, the inverter can
be destroyed due to moisture and dust penetration. All the
warranty claim will be invalid.
6.9.1
Inverter demand response modes-DRMs(Australia only)
This series inverter has the function of demand response modes, We use 8Pin COM PORT as
inverter DRED connection.
Information
DRMS application description
Only applicable to AS/NZS4777.2:2015.
DRM0-DRM8 are available.
CAUTION
Damage to the inverter due to moisture and dust penetration
Make sure the cable gland has been tightened firmly.
If the cable gland are not mounted properly, the inverter can
be destroyed due to moisture and dust penetration. All the
warranty claim will be invalid.