51
52
t
The AC Voltage Range may vary depending on specific country grid standard. All
specifications are subject to change without notice.
*DC Switch is not available on the Australian model
Rated output current
20A
21.7A
26A
Nominal output current
20.9A
22.7A
27.2A
Inrush current
<
10A/5ms
<
62A/20us
M a x . o u t p u t o v e r l o a d
protection
25A
32A
32A
Backfeed current
0A
Power factor(@nominal power)
>0.99
Adjustable power factor
0.8leading… 0.8lagging
THDi
AC grid connection type
Single phase(L/N/PE)
AC overvoltage category
Category III
AC input quantities
Nominal AC input voltage
230V
AC input voltage range
160-276V
AC input current(maximum
continuous)
20.9A
22.7A
27.2A
Inrush current
<
10A
Nominal frequency
50/60Hz
AC input frequency range
45-55Hz/55-65Hz
Max. efficiency
98.4%
98.4%
98.4%
Euro-eta
97.5%
97.5%
97.5%
DC reverse-polarity protection
Integrated
DC switch
*
Integrated
DC Surge protection class
Insulation resistance
monitoring
Integrated
AC surge protection
AC short-circuit protection
Integrated
Ground fault monitoring
Integrated
Grid monitoring
Integrated
Anti-islanding protection
Integrated(Active Frequency Drift)
Residual-current monitoring
unit
Integrated
General data
Dimensions (W / H / D) in mm
Weight
10.8 kg
Operating temperature range
–
25 °C ... +60 °C
Noise emission (typical)
<
25 dB(A)
4000m
<5W@storage
mode
Topology
Non-isolated
Overvoltage category
PV:II AC:III BAT:II Others:I
Cooling
Natural convection
Protection degree
IP65
Pollution degree outside
the enclosure
Pollution degree inside
the enclosure
Relative humidity
DC connection
Helios H4-R/VP-D4
AC connection
AC connector
Interfaces
Display
RS485/USB
Integrated
Optional
Warranty:5/10 years
Yes/ Optional