1.2.1 Installation and Wiring of Electric Meter SM-US-200
Fig 1.4 ARO Battery Wiring Diagram
Fig 1.5 ATS-5K Wiring Diagram
Fig 1.6 ATS-11.4K Wiring Diagram
a) Meter Mounting
Ø
The meter should be mounted in a Power Distribution Box.
Ø
Mount the meter on a 35mm DIN rail.
b) CT Installation
Install the two CTs with the Arrow pointing to the LOAD.
Ø
Make sure the CT of L1 matched L1 input of the Service Panel that also match the L1 to
the inverter.
Ø
Make sure the CT of L2 matched L2 input of the Service Panel that also match the L1 to
the inverter.
c) Meter Wiring
Ø
When connecting the meter to the inverter, refer to the connection diagram below.
Fig 1.8
Fig 1.7
Fig 1.9
Ø
RS485 cables Ground, B- & A+ was installed from the left to right when facing the
meter
,
Please refer to the silk screen on the meter.