4
Inspection of delivery
4.1 Unpacking and inspection
Instruction
5
5.1 Safety instruction
5.2 Selecting the installation location
The inverter is thoroughly tested and inspected strictly before delivery. Our inverters
leave our factory in proper electrical and mechanical condition. Special packaging
ensures safety and careful transportation. However, transportation damage may still
occur. The shipping company is responsible in such cases. Thoroughly inspect the inverter
upon delivery. Immediately notify the responsible shipping company if you discover any
damage to the packaging which indicates that the inverter may have been damaged or if
you discover any visible damage to the inverter. We will be glad to assist you, if required.
When transporting the inverter, the original or equivalent packaging should be used, and
the maximum layers for original carton is four, as this ensures safe transport.
After opening the package, please check the contents of the box. It should contain the
following, Please check all of the accessories carefully in the carton. If anything missing,
contact your dealer at once.
Danger to life from electric shock due to high voltages
High voltages are present in the DC cables and later during
operation in the conductive components of the inverter. These
can cause fatal electric shocks.
Danger to life due to fire or explosion
Despite careful construction, electrical devices can cause fires.
Do not install the inverter on easily flammable materials and where
flammable materials are stored.
Risk of burns due to hot enclosure parts
The surface of the inverter can become very hot. Touching the surface
can result in burns.
Do not touch hot surfaces.
During operation, do not touch any parts other than the lower
enclosure lid of the inverter.
Mount the inverter in such a way that it cannot be touched inadv-
ertently.
This is the guidance for installer to choose a suitable installation location, and to avoid
potential damages to device and operators. Rain-tight or wet location hubs that comply
with the requirements in the Standard for Conduit, Tubing, and Cable Fittings, UL 514B,
are to be used.
The unit shall be mounted at least 36inch (3 feet) above the ground. The installatio
location must be suitable for the inverter's weight and dimensions for a long period time.
Select a wall or solid vertical surface that can support the PV-Inverter.
Select the installation location so that the status display can be easily viewed.
Select a well-ventilated location sheltered from direct sunlight and rain.
Do not install the inverter on structures constructed of flammable or thermo labile
materials.
The humidity of the installation location should be 0~100% without condensation.
The installation location must be freely and safely to access at all times.
When possible, mount the inverter vertically or tilted backwards by max. 15°. And make
sure the connection of inverter must be downwards. Never install horizontal and avoids
forward and sideways tilt.
DANGER
DANGER
WARNING
Fig 4.1
Object
Description
Quantity
A
MIN XH-US inverter
1
B
Manual
1
C
Mounting bracket
1
D
Self-tapping screw
3
E
Plastic expansion pipe
3
F
Connector for RS485
1
G
Connector for Meter RS485
1
H
Safety-lock screw
2
I
Cord end terminal for AC side wiring
5
J
Cord end terminal for DC side wiring
16
K
R type terminal for grounding
1
L
Antenna
1
M
22# Blank cap
2
N
28# Blank cap
4
13
14