10
Decommissioning
10.1 Dismantling the Inverter
10.2 Packing the Inverter
10.3 Storing the Inverter
10.4 Disposing of the Inverter
11
Growatt Warranty
Please refer to the warranty card.
Do not dispose of faulty inverters or accessories together with
household waste. Please accordance with the disposal regulations for
electronic waste which apply at the installation site at that time. Ensure
that the old unit and, where applicable, any accessories are disposed of
in a proper manner
Store the inverter in a dry place where ambient temperatures are always between -22
℉
to
149
℉(
-30
℃
to 65
℃).
If possible, always pack the inverter in its original carton and secure it with tension belts.
If it is no longer available, you can also use an equivalent carton. The box must be
capable of being closed completely and made to support both the weight and the size of
the inverter.
1.Disconnect the inverter as described in section 6.
2.Remove all connection cables from the inverter.
3.Screw off all projecting cable glands.
4.Lift the inverter off the bracket and unscrew the bracket screws.
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled down.
CAUTION
Model
MIN
3000TL
–XH-US
MIN
3800TL-
XH-US
MIN
5000TL-
XH-US
MIN
6000TL
-XH-US
MIN
7600TL-
XH-US
Input data(PV)
Max. recommended
PV power(for
module STC)
4500W
5700W
7500W
9000W
11400W
DC/AC Ratio
1.5
Max. DC voltage
600V
Startup voltage
50V
Nominal voltage
360V
Operating MPPT
range
50~550V
No. of MPP trackers
2
3
No. of PV strings per
MPP trackers
2/2
2/2/2
Max. input current
per MPP trackers
12.5A
Max. short-circuit
current per MPP
trackers
16.6A
Input/Output Data (Battery)
I/O Voltage range
360V~550V
Nominal DC Voltage
360V
I/O DC Current
15A
I/O DC Power
5000W
Battery Technology
LFP
Battery Capacity per
module
9.9kWh
Scalability
Up to 4
12.1 Specification
Technical Data
12
53
54