Warranty: 10 / 12
years
yes/optional
RSD(NEC2017
690.12)
Integrated
Revenue Grade Meter
ANSI C12.20
(
meet 0.5% accuracy
)
Certification
Grid support
regulation
IEEE1547,CA Rule21,Rule14(HECO Compliant)
EMC
FCC Part15 Class B
Safety
UL1741,UL1741SA,CSA C22.2,UL1998,UL1699B,UL1741 CRD
12.2 Efficiency curve
The inverter can be operated in an ambient temperature from -13
℉
to 140
℉
(-25
℃
to
60
℃
).The MIN TL-XH-US series inverter operate at full power and full currents up to a
certain temperature, above which they may operate with reduced ratings to prevent
device damage. The following diagram illustrates how the output power of the solar
inverter is reduced automatically in accordance with ambient temperature.
The device should be installed in a well-ventilated, cool and dry location.
Due to tolerance of temperature sensor and inverter efficiency difference under different
PV voltage, this derating curve may be a little different from each.
12.3 Ambient temperature
Fig 12.2
Fig 12.1
57
58