7 Commissioning Error Code 

   Troubleshooting 

  

Enter the local commissioning home page, and view the fault and alarm information on 
the main interface if there are exist after installation. The fault and alarm code on the 
ShineServer Page will be the same in the APP. 
If you find a fault or alarm, please click it, and then you will be redirected to the interface 
of fault explanation and handling tips.

1. Common Fault and warning Codes

 

Fault code

Fault name

Possible cause

suggestion

Error 200

AFCI Fault

There is a problem on 

the wiring connection

1.After shutdown, check the

   panel terminal. 

2.Decrease AFCI sensitivity

   and restart.     

   3.If error message still exists,

   contact manufacturer. 

Error 201

Residual current 
High

PV panel insulation 
problem

1.Restart inverter. (Related
   to Grounding fault?)
 2.If error message still exists,
   contact manufacturer.

Error 202

PV Voltage High

Too many PV panels 

connected in series

1.Immediately disconnect the

   DC switch and check the PV

   voltage.

2.If the fault code still exists 

   after the normal voltage is

  restored, contact manufacturer.

Error 203

PV Isolation Low PV panel insulation 

problem

1. Check PV panel and wiring.

Error 204

PV Reversed 

PV positive and 
negative are 
reversed

1.After shutdown, Check the
   inverter terminal.
2. Restart inverter.
3.If error message still exists,
   contact manufacturer.

Error 300

AC overvoltage

Grid voltage 
overvoltage

1.Check grid voltage.
2. If the error message still exists
   despite the grid voltage being
   within the spec range, contact
   manufacturer.

Error 301

AC reversed

AC wiring error

1.Check AC terminals.

2.If error message still exists,

   contact manufacturer.

Error 302

No AC 

Connection

No AC Connection

1.After shutdown, Check AC

   wiring.

2. If error message still exists,

    contact manufacturer.

Error 303

NE abnormal

N or PE wring error

1.Check PE wiring.
2.Check N wiring.

Error 304

AC F Outrange

Abnormal grid 

frequency

1. Restart inverter.

2. If error message still exists, 

   contact manufacturer.

Warning 

217

BDC Abnormal 

ARO battery error

1.Check ARO battery terminals

2.Check the connection.

   between the inverter and the 

   ARO battery.

Warning 

218

BDC Bus 

Disconnect

Inverter and BDC 

wiring failure

1. Check the wire connection

    between the inverter and the

    ARO battery.

2.If error message still exists,

   contact manufacturer.

Summary of Contents for MIN 3K-11.4KTL-XH-US

Page 1: ...00 Download Manual Growatt New Energy Growatt USA Inc 9227 Reseda Blvd 435 Northridge CA 91324 USA 1 866 686 0298 www growatt america com T E usaservice ginverter com W MIN 3K 11 4K TL XH US Commissi...

Page 2: ...rk 3 Grid Code Mapping Table 4 Wi Fi Network Configuration 5 Energy Management System 5 1 Management System Mode Introduction 5 2 Energy Management System setting 6 Battery Life Maintenance 7 Troubles...

Page 3: ...ergen cy stop switch AC SYN 200 XH US Optional Optional MIN3 11 4KTL XH US Inverter MIN3 11 4KTL XH US Inverter PV MIN XH US Inverter L1 L2 N Back up L1 L2 AC Grid Ground bar L1 PV MIN XH US Inverter...

Page 4: ...nergy storage UP TO 2 ATS SYN 200 XH US EPS switching Smart meter SM US 200 Energy management Button RSD Button Rapid shutdown Accessory included in the package Power on the system according to the MI...

Page 5: ...onnect the inverter with built in WIFI at close range We can view the inverter system information and system fouction settings with it 2 3 Connecting to Local Wi Fi Network The steps for using APP are...

Page 6: ...nsuccessful and you will need to reconnect the build in WIFI of the inverter by turning off Wifi setting in the phone and turn on again OR power cycle the system Also keep the mobile phone within 3 me...

Page 7: ...low voltage power grid 7 PRC Quebec 208 Canada Quebec low voltage power grid 8 PRC Quebec 240 Canada Quebec low voltage power grid 9 RULE21 208 US California low voltage power grid 10 RULE21 240 US Ca...

Page 8: ...nagement System Mode Introduction The MIN 3K 11 4K TL XH US system provides four energy storage modes to choose from Storage Mode Description TOU Battery Charging Charge battery from PV production and...

Page 9: ...s Disabled 1 Tap in Charge and Discharge Management 2 Find Enable AC Charging 3 Tap in ON OFF button 14 5 2 1 Power Sensor Setting If an electric meter is installed in the system please set Factory De...

Page 10: ...XH US needs to set the off grid and electric meter enable Factory Default is disable Off Grid enable settings are as follows please refer to chapter 5 2 1 for meter settings 1 Tap in EMS 2 Tap in Tim...

Page 11: ...eriods you need to operate step 4 5 6 multiple times You can also set the energy storage mode for special days if necessary Battery Life Maintenance 6 a TUnplug Battery power Battery Communication cab...

Page 12: ...estored contact manufacturer Error 203 PV Isolation Low PV panel insulation problem 1 Check PV panel and wiring Error 204 PV Reversed PV positive and negative are reversed 1 After shutdown Check the i...

Page 13: ...terface and log into the account after the registration is completed 8 2 Create a power plant a When you log into your account for the first time you will be prompted to register a power plant b Click...

Page 14: ...ode through WeChat or IOS s Camera then download the APP d APP Store Search for ShinePhone from app stores download the installation package and install the ShinePhone app by following the instruction...

Page 15: ...ur PV system would be authorized and monitored by your installer 3 Fill the plant info 4 Continue fill the plant info 5 Tap in skip 6 Add collector 26 25 7 The Plant page display the list of plants un...

Reviews: