1.1.1 System Configuration Contains
1.2 Check System Installation & Power On
All components were installed according to the installation guides, please check the
following highlighted installation locations:
Energy Storage System / Off-Grid System.
Ø
MIN 3-11.4KTL-XH-US inverter.
Ø
ARO battery(s) or LG battery(s).
Ø
ATS.
Ø
Electric meter SM-US-200 .
Integrated in SYN 200-XH-US.
Ø
MIN 3-11.4K TL-XH-US inverter.
Ø
ATS.
Product
Model
Function
Note
Inverter
MIN 3K-11.4KTL-XH-US
Energy
conversion
ARO Battery
ARO 6.6-19.8H-C1-US
Energy storage
UP TO 4
LG Battery
RESU10H/16H Prime
Energy storage
UP TO 2
ATS
SYN 200-XH-US
EPS switching
Smart meter
SM-US-200
Energy
management
Button
RSD Button
Rapid shutdown
Accessory (included
in the package)
Power on the system according to the
MIN 3000-11400TL-XH-US Quick Guide
which is
included in the inverter package/box.
Fig 1.5 Inverter Box Wiring Diagram
Ø
ARO Battery Wiring Diagram please refer to ARO 6.6-19.8H-C1-US Quick Guide.
Ø
LG Battery Wiring Diagram please refer to LG RESU10H/16H Prime Quick Guide.
Ø
SYN 200-XH-US Wiring Diagram please refer to SYN 200-XH-US Quick Guide.
1.2.1 Communication cables installation between MIN TL-XH-US inverter and
SYN 200-XH-US
Ø
Connect the signal cable from MIN TL-XH-US inverter RS485 port to SYN 200-XH-
US,refer to the connection diagram below.
3
4
Fig 1.6