6.6
Active power control with smart meter, CT or ripple
control signal receiver
This series inverter has integrated export limitation functionality. To use this function, you can
connect the Growatt smart meter. For the detailed information, please contact with Growatt.
Fig 6.18
Active power control with a Radio Ripple Control Receiver(RRCR).
Radio ripple con-
trol receiver
Fig 6.19
Router
Public Grid
6.7
GFCI(Standard)
6.7.1
Ground Fault Circuit Interrupt(GFCI)
This inverter includes an integrated residual current device .If the leakage current is over
300mA and last for more than 300ms,the inverter will report 201 fault and the OLED will
display Residual I High.
The inverter has the function of detecting residual current and protecting the inverter against
residual current. If your inverter must equip a AC breaker which has the function of detecting
residual current ,you must choose a Type A RCD breaker with the rating residual current more
than 300mA.
26
The position of export limitation CT or Meter must between the Inverter &
Load and gird.
Information
Monitor
Summary of Contents for MOD 1 0KTL3-X
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta 15...
Page 60: ...Installations och bruksanvisning...
Page 78: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren 15...
Page 119: ...Kontaktuppgifter 19 Suomi Trading Oy Areenakatu 7 37570 Lemp l asiakaspalvelu suomitrading fi...
Page 120: ...Installation Operation Manual...
Page 138: ...Fig 5 9 Schematic diagram of inverter wall mounting 15...
Page 179: ...Contact us 19 Suomi Trading Oy Areenakatu 7 37570 Lemp l asiakaspalvelu suomitrading fi 56...
Page 180: ......