Warning
message
Description
Suggest
Warning 207 U d i s k over-current
protection
1 .Unplug the U disk
2.Re-access U disk after shutdown
3.If the error message still exists, contact
manufacturer.
Warning 208 DC Fuse Open
1 .After shutdown,Check fuse.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 209
The DC input voltage is
e x c e e d i n g t h e
m a x i m u m t o l e r a b l e
value.
1 .Immediately disconnect the DC switch and check
the voltage
2.If the fault code still exists after the normal voltage
is restored, contact manufacturer.
Warning 210 PV Reversed
1 .Check PV input terminals
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a c t
manufacturer.
Warning 300 No Utility
1 .Please confirm grid is lost or not.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 301 Grid voltage outrange
1 .Check the AC voltage is in the range of standard
voltage in specification.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 302 Grid frequency outrange
1 .Check the frequency is in the range of specification
or not.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 303 EPS mode, over load
1 .Please reduce the load of EPS output.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 304 CT Open or Wrong
1 .Check if AC current sensor is connected well 2 . I f
e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct manu-
facturer.
Warning 305 CT line reversed or
Ground fail
1.Check the L line and N line of SP-CT is reversed or
not.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 306 Communication fault M3
didn't receive SP-CT
data
1 .Check communication wire
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a ct
manufacturer.
Warning 307 Communication fault
1 .Check communication wire.
2 . If e r r o r m e s s a g e s t i l l e x i s t s , co n t a c t
manufacturer.
Warning 400 Fan function abnormal 1 .After shutdown,Check the fan connection.
2. replace the fan.
3.If the error message still exists, contact manufac-
turer.
39
Summary of Contents for MOD 1 0KTL3-X
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta 15...
Page 60: ...Installations och bruksanvisning...
Page 78: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren 15...
Page 119: ...Kontaktuppgifter 19 Suomi Trading Oy Areenakatu 7 37570 Lemp l asiakaspalvelu suomitrading fi...
Page 120: ...Installation Operation Manual...
Page 138: ...Fig 5 9 Schematic diagram of inverter wall mounting 15...
Page 179: ...Contact us 19 Suomi Trading Oy Areenakatu 7 37570 Lemp l asiakaspalvelu suomitrading fi 56...
Page 180: ......