background image

Danger

Warning

16

15

Inverter wiring

 

6

6.1 Security

There may be a high voltage in the conductive part of the inverter, 

which  may  cause  electric  shock.Therefore,  when  installing  the 

inverter,make  sure  that  the  AC  and  DC  sides  of  the  inverter  are 

powered off.

Static  electricity  may  damage  the  electronic  components  of  the 

inverter.Anti-static  measures  should  be  taken  during  the 

replacement or installation of the inverter.

Moisture and dust penetration can damage the inverter

Ø

Make sure that the waterproof cable gland is firmly tightened.

Ø

If  the  cable  connector  is  not  installed  correctly,  the  inverter 

may be damaged due to the penetration of moisture and dust. All 

warranty claims are void

Note

6.2 AC side wiring

Before  making  electrical  connections,  please  make  sure  that  the 

DC switch of the inverter is in the "OFF" state and disconnect the 

AC  side  MCB,  otherwise  the  high  voltage  of  the  inverter  may 

cause death.

Ø

Each

 

inverter

 

must

 

be

 

installed

 

with

 

an

 

AC

 

circuit

 

breaker

 

independently

and

 

it

 

is

 

forbidden

 

to

 

share

 

multiple

 

inverters

.

Ø

It is forbidden to use single-core wire at the output terminal of 

the inverter.

Ø

It is forbidden to use aluminum wires as output cables.

Ø

Please

 

ensure

 

that

 

the

 

output

 

cable

 

is

 

well

 

connected

 

before

 

turning

 

on

 

the

 

inverter.Ignoring

 

the

 

above

 

warning

 

may

 

damage

 

the

 

machine

 

or

 

cause

 

other

 

losses.In

 

this

 

case,

 

the

 

company

 

reserves

 

the

 

right

 

not

 

to

 

carry

 

out

 

the

 

warranty

 

and

 

bear

 

any

 

responsibility

 

and

 

related

 

expenses

.

Moisture and dust penetration can damage the inverter.

Ø

Make sure the cable connector is securely tightened.

Ø

If  the  cable  connector  is  not  installed  correctly,  the  inverter 

may  be  damaged  by  moisture  and  dust.  All  warranty  claims  are 
invalid.

Danger

Warning

Note

Residual

 

current

 

protection

 

device

 (

RCMU

)

Because

 

the

 

inverter

 

itself

 

has

 

a

 

high-precision

 

residual

 

current

 

detection

 

device,it

 

is

 

not

 

recommended

 

to

 

install

 

a

 

leakage

 

protection

 

switch

 

in

 

the

 

system.If

 

for

 

some

 

special

 

reason,it

 

must

 

be

 

installed

 

between

 

the

 

inverter

 

output

 

and

 

the

 

grid.Please

 

install

 

a

 

type

 

B

 

leakage

 

protection

 

switch

 

above

 

300mA

.

When

 

multiple

 

leakage

 

protection

 

switches

 

are

 

installed

 

in

 

the

 

system,it

 

is

 

forbidden

 

to

 

share

 

the

 

neutral

 

line,otherwise

 

the

 

leakage

 

protection

 

function

 

may

 

be

 

triggered

 

by

 

mistake

 

and

 

cause

 

the

 

switch

 

to

 

trip

.

Fig 5.9 Schematic diagram of inverter wall mounting

Summary of Contents for MOD 10KTL3-X

Page 1: ...Shenzhen P R China No 28 Guangming Road Shiyan Street Bao an District Shenzhen P R China 86 755 2747 1942 www ginverter com www ginverter com T E W service ginverter com service ginverter com 86 755 2747 1942 Download Manual Growatt New Energy Installation Operation Manual GR UM 212 A 00 ...

Page 2: ...ication of skilled person 2 3 Safety instruction 4 Unpacking inspection 5 Installation 5 1 Basic installation requirements 5 2 Mounting wall mount 5 3 Installing the inverter 6 1 Security 6 2 AC side wiring 6 3 DC side wiring 6 4 Connect the signal cable 6 5 Grounding the inverter 6 6 Active power control with smart meter CT or ripple control signal receiver 6 7 Inverter demand response modes DRMS...

Page 3: ... 15 Decommissioning 17 Specification 16 EU declaration of conformity 18 EU declaration of conformity 9 1 Boot display 9 2 OLED display wake up 9 3 Function setting 12 1 Start the inverter 12 2 Shut down the inverter 9 OLED display and touch buttons 19 Contect us 12 Start the inverter and shut down the inverter 10 Communication and monitoring 11 Maintenance and Cleaning 10 1 RS485 10 2 DRM 10 3 USB...

Page 4: ...ion of part or all of the Growatt device and or other equipment connected to the Growatt device or cause personal injury 1 3 2 Markings on this product CAUTION CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury Information that you must read and know to ensure optimal operation of ...

Page 5: ...communication products to communicate with each other The wireless communication device is not standard Require to order extral if you need it Safety 2 2 1 Product description and features 2 1 1 Product description Growatt series photovoltaic inverters are used to convert the direct current generated by photovoltaic panels into alternating current and send it to the grid in a three phase manner Gr...

Page 6: ...rrect installation and operation may lead to serious safety and shock hazards and or equipment damage Ø In order to minimize the possibility of shock hazards due to dangerous voltages cover the entire solar array with dark colored materials before connecting the array to any equipment Ø Grounding the PV modules MOD TL3 X is a transformerless inverter which means there is no galvanic separation Do ...

Page 7: ...nough charge to create a shock hazard In order to minimize the occurrence of this situation observe all corresponding safety symbols and marks in this manual Ø Under special circumstances the inverter may be subject to electromagnetic interference from surrounding equipment At this time the user is obliged to take correct measures to reduce the interference from surrounding equipment to the invert...

Page 8: ...4 Before opening the inverter package please check whether the outer package is damaged After unpacking please check whether the appearance of the inverter is damaged or lack of accessories If there is damage or missing parts please contact the dealer No Description Qty A Inverter 1 B Quick Installation Manual 1 C Wall mount 1 D AC waterproof cover just for Vietnam models 1 E Datalogger 1 F COM po...

Page 9: ...ty of the installation environment should be between 0 and 90 Ø The ambient temperature around the inverter should be between 25 C 60 C Ø The inverter can be mounted on a plane that is tilted vertically or backwards Please refer to the following figure Ø In order to ensure the normal operation of the machine and the convenience of personnel operation please pay attention to provide sufficient clea...

Page 10: ...ge be sure to check the wall for power or other piping before opening the hole in the wall Danger Secure the wall mount as shown do not let the screws flush with the wall instead expose 2 to 4 mm 5 3 Installing the inverter Note Before installing the inverter you must first make sure that the wall mount is firmly fixed to the wall steps 1 Hang the inverter on the wall mount and keep the inverter b...

Page 11: ...ngle core wire at the output terminal of the inverter Ø It is forbidden to use aluminum wires as output cables Ø Please ensure that the output cable is well connected before turning on the inverter Ignoring the above warning may damage the machine or cause other losses In this case the company reserves the right not to carry out the warranty and bear any responsibility and related expenses Moistur...

Page 12: ...cations of the AC output switch are as follows Inverter model Switch specification Inverter model Switch specification MOD 3000TL3 X 10A 230V MOD 9000TL3 X AU 20A 230V MOD 4000TL3 X 10A 230V MOD 10KTL3 X 25A 230V MOD 5000TL3 X 15A 230V MOD 10KTL3 X AU 25A 230V MOD 6000TL3 X 15A 230V MOD 11KTL3 X 25A 230V MOD 7000TL3 X 15A 230V MOD 11KTL3 X AU 25A 230V MOD 7000TL3 X AU 15A 230V MOD 12KTL3 X 25A 230...

Page 13: ...erter In this case the company does not carry out quality assurance and assumes any responsibility Ø The maximum open circuit voltage of each string of photovoltaic modules shall not exceed 1100Vdc under any conditions Ø PV modules connected in series in each PV string are of the same specification type Ø The maximum short circuit current of each PV string must not exceed 26A under any conditions ...

Page 14: ...ng the battery panel please make sure that the DC input polarity is correct that is the positive pole of the photovoltaic module is connected to the DC input terminal marked of the inverter and the negative pole is connected to the DC input terminal marked Ø The maximum DC input current and voltage of the inverter shall not exceed the following limits Model Single maximum input current Maximum inp...

Page 15: ...on grid via the ground terminal PE WARNING Because of the transformerless design the DC positive pole and DC negative pole of PV arrays are not permitted to be grounded 6 6 Active power control with smart meter CT or ripple control signal receiver Information The position of export limitation CT or Meter must between the Inverter Load and gird This series inverter has integrated export limitation ...

Page 16: ...rate the disconnection device Do not generate power Do not generate at more than 50 of rated power Do not generate at more than 75 of rated power and reduce the reactive power as far as possible Increase power generation subject to constraints from other active DRMs Socket asserted by shorting pins 6 7 3 Using the Power Control Interface for EU Fig 6 18 Inverter RRCR Connection DRM socket RRCR 6 7...

Page 17: ...in permanent shutdown The inverter has large electrical potential differences between its conductors Arc flashes can occur through air when high voltage current flows Do not work on the product during operation When the inverter error 200 please follow the steps 6 8 3 Operation step 6 8 3 1 Turn the DC AC Switch to position OFF 6 8 3 2 Perform troubleshooting on the PV system Wait for the screen b...

Page 18: ... solar panels into AC power and export to the grid and the green LED will light up Ø When the DC voltage is lower than 140V the inverter will automatically disconnect from the grid and exit the normal operation mode When the input voltage reaches the requirement again and the grid voltage and frequency return to normal the inverter will automatically connect to the grid 8 2 Failure mode The invert...

Page 19: ...st domestic standard If the grid voltage is close to or higher than the domestic legal requirements the inverter cannot be connected to the grid After obtaining the permission of the local power operator the user can choose other voltage levels according to the voltage situation of the grid connection point Tips and disclaimers Excessive grid voltage may affect the normal use and service life of h...

Page 20: ...10 2 USB A The inverter side The inverter side The inverter side The inverter side Unistall up Install USB A port is mainly used to connect monitoring module or firmware update We can connect the external optional monitoring modules such as Shine WIFI X Shine Shine 4G X Shine LAN X etc to the USB interface for monitoring Steps for installing the monitoring module Make sure is on the front side the...

Page 21: ...ct terminal abnormal 1 Check the string terminal wiring after shutdown 2 If the fault message still exists contact the manufacturer Warning 202 DC lightning protection device alarm 1 Check the DC lightning arrester after shutdown 2 If the fault message still exists contact the manufacturer Warning 203 Panel short circuit 1 Check whether the first or second road panel or circuit is short circuited ...

Page 22: ...ct the manufacturer Warning 305 Reverse connection of current transformer 1 Check whether the current transformer is connected reversely 2 If the fault message still exists contact the manufacturer Warning 306 Communication failure of current transformer 1 Please check the communication line 2 If the fault information still exists contact the manufacturer Warning 307 Wireless CT pairing timeout 1 ...

Page 23: ...t information still exists contact the manufacturer Error 308 Pairing timeout 1 The pairing of the machine and the current transformer is overtime re pair 2 If the fault information still exists contact the manufacturer Error code Description Suggest Error 400 A b n o r m a l D C component offset 1 Restart the machine 2 If the fault information still exists contact the manufacturer Error 401 The o...

Page 24: ...attery reverse connection protection tube 1 Restart the machine 2 If the fault information still exists ontact the manufacturer Error 424 Battery voltage sampling is inconsistent 1 Restart the machine 2 If the fault information still exists ontact the manufacturer Error 425 AFCI self check error 1 Restart the machine 2 If the fault information still exists ontact the manufacturer Manufacturer warr...

Page 25: ... voltage 1100V Start voltage 200V Nominal voltage 580V MPP voltage range 140 1000V Full load voltage range 250 800V 320 850V No of MPP trackers 2 No of PV strings per MPP trackers 1 1 1 1 1 1 1 1 1 1 1 1 Max input current per MPP trackers 13 13A 13 13A 13 13A 13 13A 13 13A 13 13A Max short circuit current per MPP trackers 16 16A Backfeed current to PV array 0A Output data AC AC nominal power 3000W...

Page 26: ...T Model Specifications MOD 9000TL3 X MOD 10TL3 X MOD 11TL3 X MOD 12TL3 X MOD 13TL3 X MOD 15TL3 X Input data DC Max recommended PV power for module STC 13500W 15000W 15000W 18000W 19500W 22500W Max DC voltage 1100V Start voltage 200V Nominal voltage 580V MPP voltage range 140 1000V Full load voltage range 320 850V 400 850V 480 850V 520 850V No of MPP trackers 2 No of PV strings per MPP trackers 1 1...

Page 27: ...OPT Model Specifications MOD 3000TL3 X MOD 4000TL3 X MOD 5000TL3 X MOD 6000TL3 X MOD 7000TL3 X AU MOD 8000TL3 X AU Input data DC Max recommended PV power for module STC 4500W 6000W 7500W 9000W 10500W 12000W Max DC voltage 1100V Start voltage 200V Nominal voltage 580V MPP voltage range 140 1000V Full load voltage range 250 800V 320 850V No of MPP trackers 2 No of PV strings per MPP trackers 1 1 1 1...

Page 28: ...odel Specifications MOD 9000TL3 X AU MOD 10TL3 X AU MOD 11TL3 X AU MOD 12TL3 X MOD 13TL3 X MOD 15TL3 X Input data DC Max recommended PV power for module STC 13500W 15000W 15000W 18000W 19500W 22500W Max DC voltage 1100V Start voltage 200V Nominal voltage 580V MPP voltage range 140 1000V Full load voltage range 320 850V 400 850V 480 850V 520 850V No of MPP trackers 2 No of PV strings per MPP tracke...

Page 29: ...onnect terminal Interfaces Display OLED LED USB RS485 YES WIFI GPRS 4G RF LAN OPT 52 51 17 2 Torque Shell cover screw 22kgf cm AC terminal block 8kgf cm AC waterproof cover fixing screw 8kgf cm Security screws on the wall mount 12kgf cm Ground screw 12kgf cm 17 3 Annex Product attachments can be selected from the table below Name Brief Shine GPRS X USB interface GPRS monitoring module Shine WIFI X...

Page 30: ...ollowing information to provide you with the necessary help Ø Inverter type Ø Inverter serial number Ø Inverter error message code Ø Inverter OLED display content Ø Type and number of PV modules connected to the inverter Ø Inverter communication method With the appropriate settings the unit will comply with the requirements specified in the following standards and directives dated Dec 2018 MOD 3 6...

Reviews: