9.3 Function setting
All setting interfaces are as follows:
9.3.1 Select the protection voltage level
Fig 9.2
Fig 9.3
Fig 9.4
Fig 9.5
The factory setting of the inverter is CQC standard regulations. Customers can choose
different voltage protection levels according to the actual situation; a single touch
switches the voltage level, and two consecutive touches confirm the setting.
Voltage level
0
1
2
Set
successfully
0 standard
1 Wide voltage level 2
2 Wide voltage level 3
9.3.2 Set language
The default language is Chinese,touch twice in a row to enter the setting mode,a single
touch to switch the language, and touch twice to confirm the setting.
Language
Chinese
Language
English
Set
successfully
When the inverter leaves the factory, the grid-connected voltage and frequency are set in
accordance with NB/T 32004-2013 or the latest domestic standard;
If the grid voltage is close to or higher than the domestic legal requirements, the inverter
cannot be connected to the grid. After obtaining the permission of the local power
operator, the user can choose other voltage levels according to the voltage situation of
the grid connection point.
Tips and disclaimers
Excessive grid voltage may affect the normal use and service life of home
appliances on the grid-connected side,or cause loss of power generation.
Our company does not accept any responsibility for the related impacts and
consequences caused by enabling the automatic control function of output
voltage to connect to the grid.
9.3.3 Set COM address
The default COM address is 1.Touch twice in a row to enter the setting mode, single
touch, the number +1,touch twice in a row to confirm the setting,long press for 5S
number to return to zero.
Reset factory
AUTO TEST
Set paramerter
Set language
Set Date
2018
-12-14
Set Time
12:
30:00
Exportlimit
Set Comaddr
1
9.3.4 Set date and time
Touch twice to enter the parameter setting submenu, select the general setting,touch
twice to enter the general setting submenu, single touch to switch the display interface,
touch twice in the date and time interface to enter the setting state,single touch,number
+.
T
he inverter can support multiple touch modes: single touch, two
consecutive touches, three consecutive touches, long press for 5S.
Different types of taps have different functions. Advanced setting
password: 111