41
42
Error code
Description
Suggest
Error 413 Drive exception
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 414 Memory exception
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 415
Abnormal
a u x i l i a r y p o w e r
supply
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 416 Overcurrent
protection
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 417
The grid voltage
sampling is
inconsistent
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 418
The firmware
version of the
control board and
the
c o m m u n i c a t i o n
board do not
match
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 419
Inconsistent
leakage current
sampling
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 420
Leakage current
module is
abnormal
1. Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 421 CPLD abnormal
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 422
Redundant
sampling is
inconsistent
1.Restart the machine;
2.If the fault information still exists,contact the
manufacturer.
Error 423
Abnormal battery
reverse
connection
protection tube
1.Restart the machine;
2.If the fault information still exists,ontact the
manufacturer.
Error 424
Battery voltage
sampling is
inconsistent
1.Restart the machine;
2.If the fault information still exists,ontact the
manufacturer.
Error 425 AFCI self-check
error
1.Restart the machine;
2.If the fault information still exists,ontact the
manufacturer.
Manufacturer warranty
14
Please refer to the warranty card.
Decommissioning
15
15.1 Dismantling the Inverter
15.2 Packing the Inverter
1. Disconnect the inverter as described in section8.
2. Remove all connection cables from the inverter.
3. Screw off all projecting cable glands.
4. Lift the inverter off the bracket and unscrew the bracket screws.
CAUTION
Danger of burn injuries due to hot enclosure parts!
Wait 20 minutes before disassembling until the housing has cooled down.
If possible, always pack the inverter in its original carton and secure it with tension belts.
If it is no longer available, you can also use an equivalent carton. The box must be
capable of being closed completely and made to support both the weight and the size of
the inverter.
15.3 Storing the Inverter
Store the inverter in a dry place where ambient temperatures are always between -25°C
and +60°C.
15.4 Disposing of the Inverter
Do not dispose of faulty inverters or accessories together with household
waste. Please accordance with the disposal regulations for electronic waste
which apply at the installation site at that time. Ensure that the old unit and,
where applicable, any accessories are disposed of in a proper manner