5 Installation
5.1 Basic installation requirements
>
The wall on which the inverter is mounted must be sturdy and can withstand the weight of
the inverter for a long time (refer to the specifications in Chapter 17 for the weight of the in-
verter);
>
The installation location must match the size of the inverter;
>
Do not install the inverter on a building constructed of flammable or heat-resistant materials;
>
Install the inverter in an eye-view orientation to facilitate inspection of the OLED display
and maintenance work;
>
The machine’s degree of protection is IP66 and can be installed indoors and outdoors;
>
It is not recommended to expose the inverter directly to strong sunlight to prevent overheating
and cause power derating;
>
The humidity of the installation environment should be between 0 and 90%;
>
The ambient temperature around the inverter should be between -25 ° C ~ 60 ° C;
>
The inverter can be mounted on a plane that is tilted vertically or backwards.
Fig 5.1 Installation diagram
> In order to ensure the normal operation of the machine and the convenience of personnel opera-
tion, please pay attention to provide sufficient clearance for the inverter. Please referto the figure
below:
Direction
Minimum clearance (mm)
Above
500
Under
500
Both sides
300
Forward
300
11
Summary of Contents for MOD 10KTL3-XH
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta...
Page 57: ...Installations och bruksanvisning...
Page 75: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren...
Page 113: ...Operation Manual Installation...
Page 131: ...Fig 5 9 Schematic diagram of inverter wall mounting...
Page 169: ......