Inverter wiring 6
6.1 Security
6.2 AC side wiring
Residual current protection device (RCMU)
Because the inverter itself has a high-precision residual current detection device.it is not recom-
mended to install a leakage protection switch in the system.If for some special reason.it must be
installed between the inverter output and the grid.Please install a type A leakage protection switch
above 300mA. When multiple leakage protection switches are installed in the system.it is forbid-
den to share the neutral line,otherwise the leakage protection function may be triggered by mis-
take and cause the switch to trip.
16
Danger
Warning
Note
Danger
Warning
Note
There may be a high voltage in the conductive part of the inverter, which
may cause electric shock.Therefore, when installing the inverter,make sure
that the AC and DC sides of the inverter are powered off.
Static electricity may damage the electronic components of the in-
verter.Anti-static measures should be taken during the replacement or in-
stallation of the inverter.
Moisture and dust penetration can damage the inverter
>
Make sure that the waterproof cable gland is firmly
tightened.
>
If the cable connector is not installed correctly, the inverter may be
damaged due to the penetration of moisture and dust.
Before making electrical connections, please make sure that the DC switch
of the inverter is in the "OFF" state and disconnect the AC side MCB, oth-
erwise the high voltage of the inverter may cause death.
>
Each inverter must be installed with an AC circuit breaker inde-
pendently, and it is forbidden to share multiple inverters.
>
It is forbidden to use single-core wire at the output terminal of the in-
verter.
>
It is forbidden to use aluminum wires as output cables.
>
Please ensure that the output cable is well connected before turning
on the inverter.lgnoring the above warning may damage the machine or
cause other losses.In this case, the company reserves the right not to carry
out the warranty and bear any responsibility and related expenses.
Moisture and dust penetration can damage the inverter.
>
Make sure the cable connector is securely tightened.
>
If the cable connector is not installed correctly, the inverter may be
damaged by moisture and dust. All warranty claims are invalid.
Summary of Contents for MOD 10KTL3-XH
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta...
Page 57: ...Installations och bruksanvisning...
Page 75: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren...
Page 113: ...Operation Manual Installation...
Page 131: ...Fig 5 9 Schematic diagram of inverter wall mounting...
Page 169: ......