Note
Moisture and dust penetration can damage the inverter.
>
Make sure that the waterproof cable gland is firmly tightened.
>
If the cable connector is not installed correctly,the inverter may be damaged
due to the penetration of moisture and dust.All warranty claims are void.
The MOD series inverter has two independent inputs, as shown in the figure below:
Fig 6.5
Note: MOD 3-10KTL3-XH (2-channel string);
The following points should be concerned when choosing photovoltaic modules:
>
The photovoltaic modules of each photovoltaic string are of the same specification and model.
>
The photovoltaic modules of each photovoltaic string are connected in series with the same
number.
Connect DC terminal
Positive metal terminal
Positive connector
Fig 6.6
Negative connector
20
> Before connecting the battery panel, please make sure that the DC input polarity
is correct, that is, the positive pole of the photovoltaic module is connected to the
DC input terminal marked "+" of the inverter, and the negative pole is connected to
the DC input terminal marked
> The maximum DC input current and voltage of the inverter shall not exceed the
following limits.
Model
Single maximum input
current
Maximum input voltage
Note
MOD 3-10KTL3-XH
16A/16A
1100V
Cables
Cables
Negative metal terminal
4~6mm
2
4~6mm
2
Summary of Contents for MOD 10KTL3-XH
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta...
Page 57: ...Installations och bruksanvisning...
Page 75: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren...
Page 113: ...Operation Manual Installation...
Page 131: ...Fig 5 9 Schematic diagram of inverter wall mounting...
Page 169: ......