10 Communication and Monitoring
10.1 RS485
This series of inverters provide two RS485 ports. You can monitor one or more inverters via
RS485. The other RS485 port is used to connect a smart meter (standalone anti-backflow func-
tion).
No.
Description
Remarks
1
+ 12V
Dry junction: external relay
coil interface, power is not
more than 2W
2
COM
3
RS485A1
RS485 communication port
4
RS485B1
5
RS485A3
Meter communication port
6
RS485B3
7
RS485A2
Battery communication port
8
RS485B2
9
BAT.EN +
Battery wake-up signal
10
BAT.EN-
11
DRM1/5
Relay contact 1 input
12
DRM2/6
Relay contact 2 input
13
DRM3/7
Relay contact 3 input
14
DRM4/8
Relay contact 4 input
15
REF/GEN
GND
16
DRMO/COM
/
17
RS485A4
Backup box communication
18
RS485B4
19
CAN_H
CAN communication
20
CAN_L
10.2 USB-A
RRCR Active No
Description Power
11 K1-out 0%
12 K2-out 30%
13 K3-out 60%
14 K4-out 100%
15
RelayS
„ / common node
16 / /
USB-Aport is mainly used to connect monitoring module or firmware update :
We can connect the external optional monitoring modules,such as Shine WIFI-X, Shine Shine 4G-
X, Shine LAN-X, etc. to the USB interface for monitoring.
Steps for installing the monitoring module: Make sure
A
is on the front side, then insert the datalog-
ger and tighten the screws.
37
connect to
RRCR Fig
10.1
Install
The inverter side
Unistall
The inverter side
The Inverter side
The inverter side
.up
Summary of Contents for MOD 10KTL3-XH
Page 1: ...Asennus ja k ytt ohje...
Page 19: ...Kuva 5 9 Kaaviokuva invertterin sein asennuksesta...
Page 57: ...Installations och bruksanvisning...
Page 75: ...Figur 5 9 Schema f r v ggmontering av v xelriktaren...
Page 113: ...Operation Manual Installation...
Page 131: ...Fig 5 9 Schematic diagram of inverter wall mounting...
Page 169: ......