Maintenance and Cleaning 11
11.1 Checking Heat Dissipation
If the inverter regularly reduces its output power due to high temperature, please improve the
heat dissipation condition. Maybe you need to clean the heat sink.
11.2 Cleaning the Inverter
If the inverter is dirty, turn-off the AC breaker and DC switch .waiting the inverter shut down .then
clean the enclosure lid, the display, and the LEDs using only a wet cloth. Do not use any clean-
ing agents (e.g. solvents or abrasives).
11.3 Checking the DC Disconnect
Check for externally visible damage and discoloration of the DC Disconnect and the cables at
regular intervals. If there is any visible damage to the DC Disconnect, or visible discoloration or
damage to the cables, contact the installer.
> Once a year, turn the rotary switch of the DC Disconnect from the On position to the Off posi-
tion 5 times in succession. This cleans the contacts of the rotary switch and prolongs the
electrical endurance of the DC Disconnect.