12 Start and shut down the inverter
12.1 Start the inverter
Before turning the inverter on, please make sure the PV/Battery input voltage and current are
within the MPPT limits.
Follow the steps below to turn the inverter on:
1 .Pull the PV/Battery and AC cable make sure there is no loose or shaking.
4. Make sure the cable polarity is correct and voltage is less than 1100V
5. Switch on the build-in DC isolator at the bottom of the inverter.
4.Switch on the PV/Battery Array and DC isolator next to your inverter, if you can not find this
switch, skip this step.
7. Switch on the Solar AC isolator if the inverter is more than 3 meters away from your switch-
board.
6.Switch on the solar supply main switch in the switch board.
12.2 Shutdown the inverter
Danger
Don't disconnect the DC connector while the inverter is connected to the grid.
Steps to turn off the inverter:
6. Disconnect the AC circuit breaker to prevent the inverter from starting again;
7. Turn off the DC switch;
8. Turn off the BAT input switch of the BAT;
9. Check the operating status of the inverter;
10. Wait until the LED and OLED display are off, indicating that the inverter is turned off.