LED showing status of SPA, it has two colors, one is green and another is red. Please turn
to 3.1 and read the detail of LED.
6.4.3 LCD display column
LCD display column is used to show the current state, basic information and fault
information. Also includes language setting, program charging/discharging priority and
system time. On default condition will take turns to display the information.
Chart 6.3
Chart 6.2
6.4.2 LED and button instruction
Vb / Cb: 488.0 V 88%
Normal
Chart 6.4
The A line's concluding information as follow:
Ø
Standby state: SPA is in standby state. No error in this state, but for other reasons,
make it in a wait state.
Ø
Normal state: SPA is normal working state.
Ø
Checking state: SPA is in self-check state, if there is no error or warning, SPA will go
to normal state or standby state. Otherwise it will go to fault state.
Ø
Programming state: SPA is in updating firmware state.
Ø
Fault state: SPA has fault information, it will be in stopped operational protection
state.
The B line's information as follow:
In normal, it will turn on page automatically, when pushing the button “UP”, the order
of the paging information as follow:
Note:
Ø
“
Down” control command (if press “up” button, command will go back).
Ø
Workmode depend on the situation. If SPA is normal state, it will show “normal”. If
SPA is standby state, it will show as “standby” etc.
Ø
Some special definitions are explained, for example: Vb means the voltage of
battery. Cb means the capacity of lithium battery (only lithium battery shows this
data). Pm means the monitor power of user.
WorkMode
Input&Output Para
WorkMode
(Lead acid )Vb:xx.xV
(Lithium )Vb/Cb:xx.xV/xxx%
Battery info
WorkMode
Grid:xxxV /xxHz
WorkMode
EPS:xxxV/xxHz
WorkMode
Po:xxxxW /xxxxVA
UPS/EPS
WorkMode
EPS:xxxxVA
WorkMode
Pbat: (+/-)XXXX W
Battery power
WorkMode
Ec_d:xxxx .x KWh
WorkMode
Ec_a:xxxx .x KWh
WorkMode
Ed_d:xxxx.x KWh
WorkMode
Ed_a:xxxx.x KWh
WorkMode
SerNo :xxxxxxxxxx
Online
BAT Charge Etoday
WorkMode
PL: (+/-)XXXXW
WorkMode
Per_Load: %
Master Power
BAT Charge Etotal
BAT Discharge Etoday
BAT Discharge Etotal
WorkMode
20XX/XX/XX/ XX:XX
WorkMode
Model :xxxxxxxxxx
WorkMode
FW Version :xxxx
WorkMode
Eac_d:xxxx.x KWh
WorkMode
Eac_a:xxxx .x KWh
AC output Etoday
AC output Etotal
WorkMode
Pex: (+/-)XXXXW
WorkMode
Pm:
(+/ -)XXXX
W
WorkMode
Eld_d:xxxx .x KWh
WorkMode
Eld_a:xxxx.x KWh
WorkMode
Etg_d:xxxx .x KWh
WorkMode
Etg_a:xxxx.x KWh
WorkMode
Etu_d:xxxx .x KWh
WorkMode
Etu_a:xxxx.x KWh
WorkMode
Eex_d:xxxx .x KWh
WorkMode
Eex_a:xxxx.x KWh
Extern PvInv Power
WorkMode
MCU:xxxxxx
WorkMode
STM3:xxxxxx
enter
enter
Load_Etoday
Load_Etotal
To Grid Etoday
To Grid Etotal
To User Etoday
To User Etotal
Extern PvInv Etoday
Extern PvInv Etotal
Load Power
offline