If you choose CEI and used SPA inverter in Italy, SPA inverter have Auto Test function.
How to use the Autotest functions. Please see the annex.
6.4.4 work mode set up
You can enter set up page by long press “enter” for 3S, in this page, you can press
“enter” or “ESC” for 1S to finish the selection, the page shows like following:
Basic Parameter
WorkMode
WorkMode
Configuration
WorkMode
Priority
WorkMode
EPS
Press
“
enter
”
key more than
3 seconds into setup mode
Press
“
down
”
key
to the next item
Press
“
enter
”
key more
than 1 seconds to make sure
Mode Change
WorkMode
ExportLimit
WorkMode
Auto Test
WorkMode
Default Set
WorkMode
DiagnoseFun
WorkMode
RS485 Seting
WorkMode
Country/Area
WorkMode
Dry Connect
WorkMode
Chart 6.6
Chart 6.7
1.Under the Basic Para, you can see the setup options below after pressing Enter for 1S
:
In the basic Parameter, you can set language (English, Italian, German), system time,
Lead-acid LV(minimum voltage of single battery, default is 11.5V), Lead-acid
CC(maximum battery charge&discharge current , default is 25A), Lead-acid
CV(maximum voltage of single battery, default is 14.5V), Lead-acid Number(number of
connected batteries, default is 12).
2.Under the EPS, you can see the setup options below after pressing Enter for 1S:
WorkMode
Language
WorkMode
English
Italiano
Deutsch
WorkMode
System time
WorkMode
xxxxY/xxM/xxD XX :XX
WorkMode
Lead-acid LV
WorkMode
11.5 V
WorkMode
Lead-acid CC
WorkMode
25 A
三级
WorkMode
Lead-acid CV
WorkMode
14.5V
WorkMode
RS485 Addr
WorkMode
COM Address :
1
三级
WorkMode
Lead-acid Number
WorkMode
12
Basic Parameter
WorkMode
Press “Enter ” key
more than 1 seconds
to make sure
Press “Enter” key
more than 1 seconds
to make sure
Press “Down ”
key to the
next item
Only display
when battery
type is lead -
acid
Range from 10 to
12V, and the
accuracy is 0.1V
Range from 1 to
25A, and the
accuracy is 1A
Range from 12 to
15V, and the
accuracy is 0.1V
Can only be set to
12/18/24/36
WorkMode
EPS
WorkMode
WorkMode
WorkMode
EPS: Enable
Disable
ACVolt: 230 V
240
208
WorkMode
AC Freq: 50 Hz
60
Press
“
down
”
key to the next item
Press
“
enter
”
key to
make sure
WorkMode
WorkMode
N_PE Relay : ON
OFF
WorkMode
WorkMode
Bypass: ON
OFF