5
6
3 Product Description
3.1 Growatt SPA series inverter
Marks of SPA
Mark
Description
Explanation
Push-button
Status symbol of SPA
Operation of display screen and set system
Green light on
Red light on
Green light blinking
Red light blinking
SPA run normally
fault state
Alarm state
Software updating
3.2 Label Explanation
Label contains the following information: for example SPA 10000TL3 BH-UP shows as below:
Caution: risk of danger!
Danger to life due to high voltage in SPA.
There is residual voltage in SPA, SPA requires 5 minutes to
discharge.
Please wait 5 minutes before you open the upper lid or the DC lid.
Protective conductor terminal
Direct Current(DC)
Alternating Current(AC)
Refer to the operating instructions.
The machine complies with the requirements of the applicable
CE guidelines
Max. output apparent
power
Nominal voltage
Max input/output
current
Stand alone data
Nominal AC output
power
Safety level
Power factor range
Nominal AC output
voltage
Ingress protection
Model name
Nominal input/output
power
Operation ambient
temperature
Class I
IP65
0.8leading~0.8lagging
-25°C
-
+60°C
50/60 Hz
SPA 10000TL3 BH-UP
X
AC input/output data
Nominal frequency
Nominal AC output
frequency
Battery data
15/10 kW
Battery voltage range
10 kVA
Max. charging and
discharging current
22.7/15.2 a.c.A
Others
100-550 d.c.V
10 kW
AC Coupled Inverter
Made in China
VDE0126-1-1
230/400 a.c.V
50/60 Hz
25 d.c.A
Type of battery
3W/N/PE
230/400 a.c.V
Lithium / Lead-acid