Introduction

1.1 Overview

1.2 

Target Group

This  manual  will  provide  detailed  product  information  and  installation  instructions  for 

users  of  the  SPA  series  of  AC  coupled  from  Shenzhen  Gowatt  New  Energy  Technology 

Co.Ltd.  (hereinafter  referred  to  as  Growatt).  Please  read  this  manual  carefully  before 
using this product, and keep this manual in a place that is easy for installation, operation, 

and maintenance personnel to obtain. 

Any changes to this manual by Growatt will not be notified to the user. You may refer to 
the Growatt website (

) for the most updated version.

 www.ginverter.com

2

 

Safety

2

.

1

 

Safety

 

Overview


to  failure  to  install  according  to  the  instructions  in  this  manual,  Growatt  reserves  the 
right not to guarantee the quality.
•All  operations  and  wiring  must  be  performed  by  trained  and  professional  electrical 
technicians.
•When  installing,  do  not  touch  the  other  parts  of  the  inside  of  the  chassis  except  the 
terminal block.
•All electrical connections must comply with local electrical safety standards.
•If  the  equipment  requires  maintenance,  please  contact  the  local  designated  system 
installation and maintenance personnel.
•The  use  of  equipment  for  grid  connection  requires  permission  from  the  local  power 
supply department.

Please read this manual carefully before installation. If the equipment is damaged due 

Handling

Electrical connections:

Repair and replacement:

SPA is heavy, please be careful to carry it out to prevent it from 

falling 

off.

•Must be operated by a trained professional electrical technician and
 follow this manual and local regulations.
•Do not touch the inverter at will because of high voltage danger.
•Do not place flammable or explosive materials around the SPA.

•It must be operated by a trained professional electrical technician and 

adhere to this manual.

•Be sure to disconnect the battery and Grid for at least 5 minutes 

before operation to avoid danger. Please perform all operations after 

power off.

•Risk of high voltage, be careful of electric shock.

•An  AC circuit breaker must be installed for each SPA, and multiple 
SPA are prohibited from sharing.
•The cable is thick. Do not shake it tightly after tightening the cable 
terminals.  Make  sure  that  the  terminals  are  well  connected  before 
starting  SPA.  In  case  the  terminal  is  loose,  it  will  cause  overheating 
damage.
•Please confirm the positive and negative poles before connecting the
battery to the SPA.

For inverters that are no longer in operation in the future, users need 
to properly dispose of them.

1

2

Please read this manual carefully before installation. If the equipment is

not damaged according to the instructions in this manual, Growatt 

reserves the right not to guarantee the quality.

WARNING

CAUTION

WARNING

DANGER

DANGER

DANGER

WARNING

WARNING

SPA must be installed by a professional electrician who is qualified for the relevant part 

of  the  certification.  By  reading  this  manual  in  detail,  the  installer  can  install  the  SPA 

series  correctly  and  quickly,  and  can  perform  troubleshooting  and  communication 

system construction.

If  there  are  any  problems  during  the  installation  process,  the  installer  can  log  on  to 

 to leave a message or call customer service h86 0755 27471 

942.

 

www.ginverter.com

Before proceeding with the installation, make sure that the SPA does 

not have any electrical connections.

environment, spacing, etc.

•Install the SPA in a dry and ventilated position, otherwise the SPA may 

be affected.

•Please refer to this manual for the installation procedure. Please

read it carefully before installation.

Please refer to the contents of this manual for the installation 

Installation:

Summary of Contents for SPA 1000TL BL

Page 1: ...52 A 00 SHENZHENGROWATTNEWENERGYTECHNOLOGYCO LTD No 28GuangmingRoad ShiyanStreet Bao anDistrict Shenzhen P R China T 86 755 27471942 E service ginverter com W www ginverter com Installation Operation...

Page 2: ...w 2 2 Symbols Explanation 3 1 Function 3 2 Models 3 3 Apperance 3 4 Dimensions 3 5 Nameplate 3 6 Storage 3 Product Introduction 4 Unpacking 5 Installation 5 1 Basic Installation Requirem ents 5 2 Tool...

Page 3: ...nverter 12 4 Disposing of the SPA Inverter 13 1 SPA Series Energy Storage Machine Product Specification 13 2 Torque 13 3 Appendix 6 Commissioning 12 Decommissioning 7 Start up and Shut Down SPA System...

Page 4: ...t must be operated by a trained professional electrical technician and adhere to this manual Be sure to disconnect the battery and Grid for at least 5 minutes before operation to avoid danger Please p...

Page 5: ...cable CE guidelines 4 3 Product Introduction 3 3 1 Function 3 2 Models 3 3 Apperance SPA series are the AC Coupled inverter which can store energy into battery with or without existing grid tied inver...

Page 6: ...ies 474 428 178 590 17 Nameplate contains the following information Take SPA3000 as an example Table 3 1 Table 3 2 Fig 3 2 Fig 3 3 place The stored temperature range is 25 C 60 C storage humidity rang...

Page 7: ...ze of the SPA series Do not install the inverter on a building constructed of flammable or non heat resistant materials SPA series s degree of protection is IP65 and can be installed indoors or outdoo...

Page 8: ...es on the wall Fig 5 4 Fig 5 5 Fig 5 6 Table 5 1 LAN line RJ45 sequence as follow PIN 1 2 3 4 Color White orange Orange White green Blue PIN 5 6 7 8 Color White blue Green White brown Brown LAN line 1...

Page 9: ...top edge of paper board is level As the chart 5 8a below Mark four points at the wall via the hole of the paper board then remove the paper board Drill four 8 holes at the mark point the depth is not...

Page 10: ...in sequence insert cables into connection terminal according to polarities indicates on it and tighten the screws Table 5 3 Fig 5 10 Fig 5 11 Fig 5 12 Step 3 Push threaded sleeve on to connection term...

Page 11: ...connect with AC grid and EPS OUTPUT like the chart show AC grid terminal and EPS terminal can t directly connect together EPS terminal can t connect to grid If you want to use on gird and off grid you...

Page 12: ...the cable such as CT2 cable is not used please do not remove the filler plug from Fig 5 21 During the actual operation please pay attention to the installation of current transformer as the diagram sh...

Page 13: ...to the direction of the current in live wire from grid to the load Current transformer needs to be placed in the power distribution cabinet 5 4 5 Connection of meter terminal We also can use meter in...

Page 14: ...ttery manual If the cable such as RS485 cable or CAN cable is not used please do not remove the filler plug from the cable support sleeve If you are using a lead acid battery you do not need to instal...

Page 15: ...th of this cable is 1 5m so pay attention to the distance of battery and SPA series If the cable such as NTC lead acid battery temperature sensor cable is not used please do not remove the filler plug...

Page 16: ...ate power DRM6 2 5 Do not generate at more than 50 of rated power DRM7 3 5 Do not generate at more than 75 of rated power and sink reactive power if capable DRM8 4 5 Increase power generation subject...

Page 17: ...r export to the grid With inverter energy from inverter inverter is weak the battery will discharge for load firstly and the grid will supply the power when the battery power is not enough Without inv...

Page 18: ...ase refer to 9 1 6 2 2 Fault mode 6 2 4 Checking mode 6 2 5 Standby mode 6 2 6 Shutdown mode 6 2 3 Programming mode Programming mode indicate the SPA is updating don t cut out power Grid and Battery w...

Page 19: ...the model display show as 6 3 1 If the model display is match what you want it means your setting is successful 2 You need to calibrate the time that the machine is showing after SPA series starts up...

Page 20: ...ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 4 2 3 1 ON 5 6 4 Display and button 6 4 1 LCD display area Vb Cb 50V 40 Normal Location Description A Information B State C SPA inverter D Power flow line E...

Page 21: ...will be in stopped operational protection state The B line s information as follow In normal it will turn on page automatically when pushing the button UP the order of the paging information as follow...

Page 22: ...ou can see the setup options below after pressing Enter for 1S In the back up you can set EPS including enable or disable default is enable AC voltage default is 230V and frequency default site 50HZ U...

Page 23: ...ow Program OK and inverter will back to normal working state Then pull out the U disk and screw the waterproof lid 6 5 Communication 6 5 1 U disk Firmware upgrade USB is only used for firmware update...

Page 24: ...ion optional WiFi connection steps Remove the RS232 port cover turn the small DIP switch Pin1 and Pin2 to ON Plug WiFi S module into the RS232 port and configure the connection between WiFi module and...

Page 25: ...disconnecting battery terminals Determine if battery is inadvertently grounded If inadvertently grounded remove source from ground Contact with any part of a grounded battery can result in electrical...

Page 26: ...C V Outrange Grid voltage fault Please refer to the local grid standard for more details of the grid voltage 1 Make sure AC voltage is in the range of local standard 2 Make sure the AC cable is well c...

Page 27: ...tput voltage low 1 Check the load of EPS If overload occurred at the same time reduce EPS load 2 Restart inverter again Error message Error message Description Suggestion Error 411 I n t e r n a l c o...

Page 28: ...ibed in this document are in compliance with the above mentioned EU directives The entire EU Declaration of Conformity can be found at www ginverter com The factory warranty card is enclosed with the...

Page 29: ...s between 25 C and 60 C Do not dispose of SPA inverter together with household waste Please accordance with the disposal regulations for electronic waste which apply at the installation site at that t...

Page 30: ...y 92 0 92 5 93 0 Max Discharge efficiency 92 5 93 0 93 5 Protection Devices BAT reverse protection yes AC surge protection yes AC short circuit protection yes Ground fault monitoring yes Grid monitori...

Page 31: ...06100 Shine Wi Fi S COM interface MR00 0008600 GRRS COM interface MR00 0009601 SP CT Wireless meter sensor MR00 0006500 SPM Single phase meter Rs485 meter sensor of Eastron MR00 0008800 13 2 Torque 13...