WARNING:
Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
4.
Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal
screws. Be sure to connect PE protective conductor
first.
5.
Make sure the wires are securely connected.
CAUTION:
Appliances such as air conditioner are required at least 2~3 minutes to restart because it‟s required
to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a
short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check
with manufacturer of air conditioner that if it‟s equipped with time-delay function before installation. Otherwise,
this off grid solar inverter will trigger overload fault and cut off output to protect your appliance but sometimes
it still causes internal damage to the air conditioner.
CAUTION: Important
Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause
utilility short-circuited when these inverters are worked in parallel operation.