17
03
AC input voltage range
Appliance (default)
If selected, acceptable AC input
voltage range will be within
154~272VAC
If selected, acceptable AC input
voltage range will be within
184~272VAC
05
Battery type
AGM (Default)
Flood
User-Defined
If “User-Defined” is selected, battery charge voltage and low DC
cut-off voltage can be set up in program 19, 20 and 21.
User-Defined 2
(Suitable for lithium battery when no communicating with BMS)
If „US2‟ is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19,20 and 21.
Lithium (Only suitable when communicate with BMS)
The lithium battery BMS communication protocol options
06
Auto restart when
overload occurs
Restart disable (default)
Restart enable
08
Output voltage
230V
220V
240V(default)
208V
09
Output frequency
50Hz (default)
60Hz