20
24
Battery
equalization
voltage
48.0V model: default 58.4V, 48~60V settgble
25
Battery equalized time
Setting range is from 5min to 900min. Increment of each click
is 1min.
26
Battery equalized timeout
Setting range is from 5min to 900min. Icrement of each click
is 1 min.
27
Equalization interval
Setting range is from 1 to 30 days.
Increment of each click is 1 day.
28
Equalization
activated
immediately
If equalization function is enabled in program 23, this
program can be set up. If “Enable” is selected in this
program, it‟s to activate battery equalization immediately and
LCD main page will shows “
”.If “Disable” is selected, it
will cancel equalization function until next activated
equalization time arrives based on program 27 setting. At this
time, “
” will not be shown in LCD main page.