25
04
Power saving mode
enable/disable
(default)
If disabled, no matter connected load is low
or high, the on/off status of inverter output
will not be effected.
Saving mode enable
If enabled, the output of inverter will be off
when connected load is pretty low or not
detected.
05
Battery type
AGM (default)
User-Defined
If “User-Defined” is selected, battery charge
voltage and low DC cut-off voltage can be
set up in program 19, 20 and 21.
Flooded
Lithium
(Only suitable when communicated with BMS)
User-Defined 2
(
suitable when lithium battery without BMS
communication
)
If “User-Defined 2” is selected, battery charge voltage and low DC
cut-off voltage can be set up in program 19, 20 and 21. It is
recommended to set to the same voltage in program 19 and 20(full
charging voltage point of lithium battery). The inverter will stop
charging when the battery voltage reaches this setting.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
08
Output voltage
230V (default)
220V
240V
208V
09
Output frequency
50Hz (default)
60Hz
10
Number of series batteries
connected
(e.g. Showing batteries are connected in 4 series)