18
05
Battery type
AGM (default)
Flooded
Lithium (only suitable when communicated with BMS)
User-Defined
If “User-Defined” is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19, 20 and 21.
User-Defined 2 (suitable when lithium battery without BMS communication)
If “User-Defined 2” is selected, battery charge voltage and low DC cut-off
voltage can be set up in program 19, 20 and 21. It is recommended to set
to the same voltage in program 19 and 20(full charging voltage point of
lithium battery). The inverter will stop charging when the battery voltage
reaches this setting.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
Restart bypass
When overload under battery mode
,
system will switch to bypass
automatically
08
Output voltage
230V (default)
220V
240V
208V
09
Output frequency
50Hz (default)
60Hz
11
Maximum utility charging
current
Note: If setting value in
Program 02 is smaller
than that in Program 11,
the inverter will apply
charging current from
Program 02 for utility
charger
Default 30A, 0A~40A Settable
(If LI is selected in Program 5, this program can’t be set up)