26
13 62fault
Fig.5 62fault
Testing method:
a) Restart the inverter, check if 62fault will disappear.
b) After restarting it, if it is still not solved. Please uncover the inverter, check if control board is
plugged into mainboard sufficiently and connection wire is loose.
c) If above all are normal, pleases try to swap control board from normal inverter. Based on the
experience, 62fault is often caused by control board. But sometimes, mainboard that is damaged
may cause 62fault. Please kindly note this.
14 80 fault
80 fault means Parallel CAN fault, it just happens on parallel mode.
Testing method:
a. Firstly, check if parallel cable is connected sufficiently and restart the inverter, and see if it can
become normal.