Appendix
10
The following chart is the inverter optional appendix list, if there is a need please
contact the Growatt New Energy Technology Co., Ltd or dealer orders.
Name
Description
ShineWiFi
COM interface by wi-fi
Shine3G
COM interface by WCDMA or GPRS
ShineLink(ShinShineRFStick)
COM interface by RF and Lan
Shine WebBox
Data record by Rs485
Table10.1
The following chart is approximate Back-up time table:
Model
Load(VA)
Backup Time
with 48Vdc 100Ah(min)
Backup Time
with 48Vdc 200Ah(min)
3KVA
300
1054
2107
600
491
1054
900
291
668
1200
196
497
1500
159
402
1800
123
301
2100
105
253
2400
91
219
2700
71
174
3000
63
155
5KVA
500
613
1288
1000
268
613
1500
158
402
2000
111
271
2500
90
215
3000
76
182
3500
65
141
4000
50
112
4500
44
100
5000
40
90
Note: Back up time depends on the quality of the battery, age of battery and type of
battery.
Specifications of batteries may vary depending on different manufacturers.
Table10.2
29