Wire suggest length:
Max cable length
Conductor cross
section
5.2mm 10AWG
2
6.6mm 9AWG
2
Growatt
SPH3000
Growatt
SPH3600
Growatt
SPH4000
Growatt
SPH4600
Growatt
SPH5000
Growatt
SPH6000
40m
33m
50m
42m
28m
36m
26m
25m
33m
32m
23m
29m
Chart 5.13
Step1: Uninstall the AC terminal and UPS terminal as above chart.
Chart 5.14
Step 2: Thread cables through pressure screw, seal ring, threaded sleeve in sequence,
insert cables into connection terminal according to polarities indicates on it and
tighten the screws.
AC output terminal and UPS output terminal connection steps as follow (Except for
the Australian machine):
Chart 5.15
19
20
AC output terminal connection steps as follow:
Step 2.Thread cables through pressure screw, seal ring, threaded sleeve in
sequence, insert cables into connection terminal according to polarities indicates
on it and tighten the screws.
chart 5.18
chart 5.19
chart 5.17
Note
:The following diagram shows the AC output terminal of the Australian
machine connection steps are as follows, UPS output terminal connection steps
consistent with the above steps.
Step 3:Push threaded sleeve on to connection terminal until both are locked tightly
Chart 5.16
Step 1: Uninstall the AC terminal as above chart.
Step 4: Plug the socket into AC output terminal and UPS output terminal,
clockwise rotation to tighten the socket, counterclockwise rotation to loosen the
socket.