57
12.1 Dismantling the energy storage
1. Disconnect the storage machine such as mentioned in section 7
.
2. Disconnect the upper cable of SPH inverter
.
Watch out the SPH’s shell heat and prevent to scald
Wait 20 minutes until the SPH cooling and then to disassembly!
3. Unscrew all the connecting cable.
4. Unscrew the radiator and wall-mounted anchor screw and then take down the
machine from wall .
12.2 Packing the SPH inverter
Usually placed SPH inverter in the packing box with tape sealing, if the SPH inverter
cannot reoccupy, You can choose a cheap carton for packaging. Carton requirements
must meet the size of the inverter and can support energy storage machine overall
weight.
12.3 Storing SPH inverter
Store SPH inverter in a dry place where ambient temperatures are always between
-
25°C and +60°C
12.4 Disposing of the SPH inverter
Do not dispose of SPH inverter together with household
waste. Please accordance with the disposal regulations for
electronic waste which apply at the installation site at that
time. Ensure that the old unit and, where applicable, any
accessories are disposed of in a proper manner.
12
Decommissioning
13
Product Specification
13.1 Growatt SPH series energy storage machine product
specification
Rated AC output
power
Model
Specifications
Input data
(
DC)
Max.
recommended PV
power(for module
STC)
Max. DC voltage
Start voltage
Normal voltage
MPP work voltage
range
Max. input current
of tracker A/
tracker B
Max. short current
Output (AC)
3300W/
3300W
3300W/
3300W
3300W/
3300W
4000W/
4000W
4000W/
4000W
4000W/
4000W
550V
150V
550V
150V
550V
150V
550V
150V
550V
150V
550V
150V
370V
370V
370V
370V
370V
370V
150V-550V
12A/12A
15A
12A/12A
15A
0A
0A
0A
0A
0A
0A
12A/12A
15A
12A/12A
15A
12A/12A
15A
12A/12A
15A
2/1
3000VA
3000W
16A
230V ;
180Vac-
270Vac
50/60,±5Hz
230V ;
180Vac-
270Vac
230V ;
180Vac-
270Vac
230V ;
180Vac-
270Vac
230V ;
180Vac-
270Vac
230V ;
180Vac-
270Vac
3680VA
3680W
16A
4000VA
4000W
22A
4600VA
4600W
22A
4999VA
4999W
22A
6000VA
6000W
27A
2/1
2/1
2/1
2/1
2/1
150V-550V 150V-550V
150V-550V
150V-550V 150V-550V
Number of
independent MPP
trackers / strings
per MPP tracker
Max. AC apparent
power
Max. output
current
AC nominal
voltage; range
AC grid
frequency; range
Backfeed current
to the array
Max inrush peak
current
34.6A
65A
65A
65A
65A
65A
65A
65A
65A
65A
65A
65A
65A
34.6A
34.6A
34.6A
34.6A
34.6A
Max output fault
peak current
Max output
overcurrent
protection
58
Growatt
SPH6000
TL BL-UP
Growatt
SPH3000
TL BL-UP
Growatt
SPH3600
TL BL-UP
Growatt
SPH4000
TL BL-UP
Growatt
SPH4600
TL BL-UP
Growatt
SPH5000
TL BL-UP