25
26
Note:
1. If you are using a lead-acid battery, you do not need to install this communication
cable.
2. If the cable such as “CAN” cable is not used, please do not remove the filler plug
from the cable support sleeve.
When using CAN communication with lithium batteries (for example HOMEe11),
connect lithium battery terminal (RJ45) steps as follows:
Step 1: Remove the locking nut and waterproofing bolt..
Step 2: Route the “CAN” cable through the conduit and then the fitting of the pipe.
Step 3: Insert the RJ45 plug of the network cable into the “CAN” pin connector on the
inverter until it snaps into place.
Step 4: If no other cables need to be installed, Secure the fitting to the conduit.
5.5.5 Connection of communication terminal for lithium battery (CAN)
C
an
5.5.6 Connection of temperature probe for lead-acid battery
When customer using lead-acid battery, the temperature probe of the lead-acid
battery is used to detect the ambient temperature of the lead-acid battery, the battery
temperature cable of the SPH side connection steps are as follows:
Step 1: Remove the locking nut and waterproofing bolt..
Step 2: Route the “NTC” cable through the conduit and then the fitting of the pipe.
Step 3:Insert the RJ45 plug of the network cable into the “NTC” pin connector on the
inverter until it snaps into place.
Step 4:If no other cables need to be installed, secure the fitting to the conduit.
Note:
1. If you are using a lithium battery, you do not need to install this temperature probe,
the probe of the temperature cable should be attached to the surrounding environment
of the lead-acid battery, and the length of this cable is 1.5m, so pay attention to the
distance of battery and SPH.
2. If the cable such as “NTC” (lead-acid battery temperature sensor) cable is not used,
please do not remove the filler plug from the cable support sleeve.
N
TC