35
36
3. Under the Priority, you can see the setup options below after pressing Enter:
Note:
1. “Power Rate” is used to set up power of battery. So different battery may have the
different power, customer need to check the max power of battery.
2. Time setting is 24-hour.If the end time is less than beginning time, it defaults to
spanning days.
4. Under the MODE Change, you can see the setup options below after pressing
Enter:
The MODE change has two options what are sensor and battery type, sensor is cable
CT (default), meter. In the battery type, you can choose lithium battery or lead-acid
battery.
WorkMode
Stop SOC: 100%
Stop SOC: 5%
WorkMode
Time
WorkMode
Power Rate: 100 %
Power Rate: 100 %
Priority
WorkMode
WorkMode
Opt: Load First
(
default
)
Bat First
Grid First
WorkMode
WorkMode
WorkMode
AC CHG: Enable
Disable
WorkMode
SC : _ _ _ _
WorkMode
00:00
–
00:00
WorkMode
Save
:
OK
NO
WorkMode
Time
WorkMode
00:00
–
00:00
WorkMode
Save
:
OK
NO
If battery first is choosen
WorkMode
Bat First: OK
NO
If you need to enable AC charging
function, you need key password
Range from 50 to 100%,
and the accuracy is 1%
Range from 10 to 100%,
and the accuracy is 10%
WorkMode
If Grid first is choosen
Grid First: OK
NO
Range from 50 to 100%,
and the accuracy is 1%
Range from 10 to 100%,
and the accuracy is 10%
Press
“
down
”
key
to the next item
Press
“
down
”
key
to the next item
choose
“
OK
”
to
the next item
choose
“
OK
”
to
the next item
Lead-acid
Press
“
enter
”
key to
make sure
MODE Change
WorkMode
Cable CT
WorkMode
Meter
Lithium
WorkMode
Press
“
enter
”
key
to make sure
Battery Type
WorkMode
Press
“
down
”
key
to the next item
Sensor
WorkMode
Exportlimit is used for users to control the energy flowing to the grid. If this function is
enabled, the feeding power to grid will be equal or less than the setup value.
The purpose of the Fail Safe function is to ensure that should any part of the ELS fail,
the Active Power exported across the Connection Point will drop to the Agreed Export
Capacity or less within the specified time.
Note:
1. Default value is 00.0%
2. Fail safe works only in meter mode
3. Fail safe works only in G99 or G98 certification.
4. If Exportlimit function is working, we can't setup priority of Grid first.
5. Under the ExportLimit, you can see the setup options below after pressing Enter:
W o r k M o d e
E x p o r tL im it
W o r k M o d e
W o r k M o d e
E x p o r tL im it : O F F
O N
P o w e r R a te : 0 0 .0 %
P r e s s “ e n te r ” k e y m o r e th a n 1
s e c o n d s to m a k e s u r e
P r e s s “ d o w n ” k e y to
th e n e x t ite m
P r e s s “ e n te r ” k e y to
m a k e s u r e
R a n g e fr o m 0 0 .0 % to
1 0 0 .0 % , a n d th e
a c c u r a c y is 0 .1 %
W o r k M o d e
F a il S a fe : O N
O F F