13
Revision date: 08.27.19 113463_64_65HBC
End Panel Installation
3
END PANEL INSTALLATION – continued
NOTE:
If conduit is an inch or two short using pipes identified on
previous page, ensure correct pipes have been used. If correct
pipes are confirmed, extend conduit by loosening one splice and
sliding pipes apart. Reinstall Tek screw in a new location and
wrap with tape.
At least 2" of a pipe must remain inside an
adjacent pipe at a splice.
4. Ensure conduit is outside pocket in door section of end panel.
Attach each end of conduit to ground post using Tek screws and
QH1330 brackets.
3. Measure between end rafter ground posts to determine final conduit
length. Cut assembled conduit to fit if needed.
NOTE:
Dashed lines identify conduit inside end panel pocket.
See call-out in diagram at the right for location of Detail A shown
above.
A
END VIEW FROM INSIDE LOOKING AT END PANEL
End Panel
End Panel
Zipper
QH1330 Bracket
Ground Level
Conduit out of panel pocket.
Wrap this material over end rafter, secure
with fabric clips, and trim excess material.
QH1330 Bracket
Dashed line shows conduit inside panel pocket.
Ground Post
QH1330 Bracket &
Tek Screws
End panel
on ground.
A
Panel Pocket