39
Revision date: 12.30.16
30' R
after P
rofile with Optional S
uppor
t Kit
2'-0"
10'-6 7/16" GROUND LEVEL TO
CENTER OF CROSS BEAM
30'-0" CENTER TO CENTER OF GROUND POSTS
WE
B
(ST08475D13G17S
1)
BAND CLAMP
(106735
)
BAND CLAMP
(106735)
BAND CLAMP
(106735
)
GROUND LEVEL
BAND CLAMP
(103856)
BAND CLAMP
(103856)
WE
B
(ST08475D13G17S
1)
WE
B
(ST05050D13G17S
1)
WE
B
(ST05050D13G17S
1)
VIEW
1
WEB TO CROSS BEAM
CONNECTION
VIEW
3
RAFTER TO CROSS BEAM CONNECTION
VIEW
2
WEB TO RAFTER
CONNECTION
VIEW
4
CROSS BEAM CONNECTION
CROSS BEAM
(S20P07237G14SS1
)
CROSS BEAM
(S20P126G14SGA
)
CROSS BEAM
(S20P126G14SGA
)
NOTE:
If rafter with support kit is positioned where mid bay
diagonal cables are located, use this bolt (each end) to secure 108503 cable bracket to rafter. See Page 21 and Quick Start diagrams for additional details.