background image

2

1.  Contact your chemical or fluid supplier to check for compatibility 

with pump prior to installation and operation.

2.  Assemble the 2 parts of the Discharge spout together & fasten 

the assembly onto the outlet on the main pump body. Use PTFE 

tape or equivalent sealant tape. Do not use paste pipe sealant. 

3.  Insert the handle shaft through the pump handle.Fix the 

pump handle onto the crank arm & connect the crank to the 

crankshaft on the pump body. Secure the connection using the 

hex bolt & hex nut provided. Make sure that the bolt fits onto 

the depression in the crankshaft.

4.  Assemble the suction tube parts, depending upon the drum 

size on which the pump is to be installed. The tail pipe with 

the strainer may be connected direct onto the pump inlet or 

assembled with one extension or both extensions, depending 

upon drum size. All 3 parts must be connected for use with 

55 gallon / 205 litre drums. It is good practice to use a sealant 

such as PTFE in connecting the suction tube parts for a totally 

leak-proof connection. 

5.  Choose the bung adapter from the two that best fits your 

drum. Each pack comes with two adapters, which have slight 
difference in the threads to suit different drums. Slide the 
selected 2” bung onto the tube from the top end & tighten 
the suction tube onto the inlet on the main pump body. It is 
good practice to use a sealant such as PTFE in connecting the 
suction tube to the pump inlet.

6.  Insert the pump assembly into the drum from the 2” bung 

opening on the drum.

7.  Once the bottom of the pump touches the base of the drum, 

securely fasten the bung onto the drum. Now very lightly 
tighten the bung onto the suction tube

PUMP ASSEMBLY & INSTALLATION

OPERATION

MAINTENANCE

Do not use the pump with Acetone, Lacquer, Mineral Oils, 
Solvents, Turpentine etc..

Take an empty container & place it below the discharge spout. Start 

rotating pump handle. Within a maximum of 7 rotations, pump will 

be primed & will start dispensing media. In a rare case, where the 

pump does not get primed, the same can be done by reversing the 

outlet discharge spout on the pump & pouring about 1 oz. of any oil 

into the outlet & operating the pump handle for about 7 rotations. 
Once you have completed pumping the media, it is a good practice 

to invert the discharge spout sideways for a non-drip operation.

Regularly check pump and suction tubes for leaks. Leaks in the 

suction line or in pump housing will cause inefficient pumping and 

loss of prime. 

SPECIFICATION

Pump Type

Rotary

Flow

8 oz. per stroke

Maximum fluid Temperature

104° F / 40° C

Mounting

2” MNPT Bung

Suction Tube Outlet O.D.

1-7/32”

Suction Tube

3 piece / Threaded

Discharge Tube Outlet O.D.

1”

Outlet Type

2 Pc curved discharge spout

Wetted Material of Construction

Stainless Steel, Ryton, Viton and Glass Filled Polypropylene

Maximum Viscosity

2000 SSU

Reviews: