Problem

Possible Cause

Corrective Action

Pump does not dispense 
fluid or does not prime

Pump not able to create adequate suction Prime the pump. Reverse the discharge spout on the pump & pour 

about 1 oz. of the fluid being pumped, into the outlet & operate the 
pump handle till fluid starts dispensing 

Pump is drawing in air, instead of fluid

Tighten all connections of suction tube & of the suction tube with 
pump inlet. Inspect pump cover(s) and seals for 
leaks. Tighten fasteners and replace gaskets / seals

Suction tube inlet is clogged

Remove suction tube & clean strainer at tube inlet

Leakage of media from the 
crankshaft

Damaged seal due to use with media not 
suitable for use with pump

Replace seal with genuine replacement seal from manufacturer

Handle difficult or 
impossible to move

Pump has not been used for a long time

Remove pump cover and inspect for deposits on components and 
corroded parts. Clean or replace parts. Flush pump with the media 
being used if pump is not in use over long periods of time.     

Damaged or worn pump parts

Remove pump cover & inspect internal parts. Replace worn or 
damaged parts

TROUBLESHOOTING