6. Open the bottle of Silentair Synthetic Oil. Using 

the Applicator Spout, carefully add the oil through 

the Air Intake opening. As an alternative, you can 

add the oil through the plug at the top of the head 

marked OIL by unthreading the knob.

7. Check the oil level on the sight glass located by 

the T-Fitting. The oil should be at the halfway mark. 

NOTE: For best operation, change and refill the oil 

with fresh Silentair Synthetic Oil after the first 150 

hours of compressor use. 

USING ANY OTHER OIL VOIDS 

THE 1-YEAR MANUFACTURER’S WARRANTY 

and will cause 

increased wear and excessive oil blow-by.

8. Install the Air Intake Filter by threading it into the 

Air Intake opening.

9. Two sets of tubing are included:

  1. Buffer Air Tubing A (Fig. A–8)

• Extra length replacement tubing for around 

the compressor pump head. 

• Allows air from the compressor to cool, 

depositing oil droplets in the tubing before 

going to the Coalescing Filter.

• Replace when Coalescing Filter is replaced, 

or if tubing becomes contaminated with oil. 

  2. Tubing B (Connects to Fig. A–5)

• 50 ft. (30.5m) long. 

  Use entire length. Coil excess.

• Connects compressor to engraving system.

10. To connect Tubing B: 

• Connect the end without a compression 

fitting to Tube B Connector (Fig. A–5). 

• Gently snug the nut using a wrench. 

• Connect the other end to engraving system.

NOTE: To connect a GraverMax SC or GraverMach, 

remove the tube fitting. Install the tube directly into 

the Quick Disconnect.

11. Follow the Installation Instructions on the 

following page to install the Auxiliary Cooling Fan.

OIL

OIL

AIR INTAKE

OPENING

OIL

OIL

AIR INTAKE

OPENING

• OPTIMAL OPERATING PSI • This compressor has 

been adjusted to provide a maximum of 80 psi (plus 

or minus 10 psi). By operating at this conservative 

80 psi pressure, the compressor stays cooler. The 

air pressure is ample for operating air tools such 

as a GraverMach, GraverMax SC, System 3, rotary 

handpieces, and other similar air tools. 

 

• DRAINING WATER • Water 

is generated as a by-product of 

compressing air. The small T-Fitting 

with the spout is for draining the air 

tank. The valve has an extension 

that goes to the tank bottom to 

allow complete system draining. 

It is not necessary to remove the 

bottom tank plug or tip the compressor on its side to 

drain water. Drain regularly as needed.

• SHIPPING • If shipping is required, remove 

ALL OIL to prevent oil leakage and damaging oil 

contamination of the air components. Do not assume 

the shipper will keep the box upright during transit. 

• USING THE RIGHT OIL • This air compressor is 

designed to be remarkably quiet and long-lasting. 

To accomplish this, it requires special oil inside the 

compressor housing. The right oil to use – Silentair 

Synthetic Oil 

(#022-163)

 – is included with the 

compressor. Call GRS to order additional bottles.

• CHANGING OIL • When changing the compressor 

oil, warm a cold machine up by running it for several 

minutes and then unplug the electric cord. Drain the 

tank of water. Remove the Air Intake Filter located in 

the compressor head. Tip the compressor over on its 

side to drain the used oil from the pump housing into 

a suitable container. Properly dispose of used oil. 

Stand machine back up on a level surface and refill 

to the correct level with fresh Silentair Oil.

For help with this product or to order additional 

supplies, please call GRS at 1-800-835-3519 or 

620-343-1084 (Monday – Friday, 8 am – 5 pm). 

Always add oil before use.

5

7

6

8

9

ADDITIONAL INSTRUCTIONS, NOTES & MAINTENANCE HINTS