HXr Installation Manual GRT Avionics
A-16
Revision A5
Legacy Magnetometer (For AHRS Part No. AAS-) Connector Pinout Diagram
All electrical connections for the magnetometer are made to the AHRS/Air Data Computer via 9-pin
D-sub connectors. The AHRS connector has these wires pre-installed, but the magnetometer cable
is provided without the connector attached for easier routing through the airframe. Use the
following diagram to attach the connector to the cable after running the wires. Be sure to inspect
the pins before inserting them into the D-sub, as damage can occur from pulling them through
holes in the airframe.
Pin
Function
Wire Color
1
MAG Y
WHT/BRN
2
MAG Z
WHT
3
MAG X
WHT/GRN
4
MAG PWR
WHT/RED
5
MAG GND
BLK
6
MAG CNTRL
WHT/BLU
7
NC
8
NC
9
NC
5
1
6
9
Male 9-pin D-sub Magnetometer
Connector as viewed from REAR