GENO
®
-flushing compressor 1988 K
Order no. 015 151 963-inter Created: KONS-gmei-mrie G:\BA-151963-INTER_GENO-SPUELKOMP-1988_K.DOC
56
4 | Maintenance
Maintenance work must be performed regularly after use, or at least
once per year, as otherwise the warranty claim will become void.
Maintenance work must be carried out by properly trained specialists or
the Grünbeck technical customer service/authorised service company.
Once per month or more frequently depending on how dirty the
ambient air is, if the system is only used periodically once per year.
Replace the air suction filter on the compressor aggregate.
Attention!
Never operate the compressor aggregate without the air
suction filter!
At least once per year, possibly more often depending on contamination
levels.
Replace the filter insert on the flushing air pressure regulator of the
flushing compressor.
As part of maintenance activities, all the work listed under "Care
work" and "Inspection" must also be performed.