![background image](http://html1.mh-extra.com/html/grundfos-alldos/oxiperm-c-164-series/oxiperm-c-164-series_operation-and-service-manual_2272215059.webp)
59
15.710010-V5.0
Oxiperm 164 150-2500 g en
●
Press "Enter" or "arrow right" to switch to the menu:
Display indicator:
Contact input <
0 g/h = 0.00 pulses/sec.
9 g/h = 8.33 pulses/sec.
The requisite installation capacity, as well as the pulses output by the water meter
are now calculated in this menu.
Example:
Default quantity of ClO2:
0.3 ppm
Main water volume:
30 m³/h
Contact water meter:
1 pulse/litre
max. installation capacity:
0.3 ppm x 30 m³/h = 9 g/h
Water meter pulses:
1 pulse/litre x 30m³/h x 1000/3600
=
8.33 pulses/sec.
NOTE
Select or set the contact water meter in such a way
that, at max. installation capacity, the control pulses
are not < 5 pulses/sec.!
●
Press "Enter" to switch to the menu:
Display indicator:
Contact input <
Flow of H2O
Max.
xxx.x m³/h
Min.
xxx.x m³/h
The max. and min. volume of water which can be supplied with ClO2 through the
set quantity to be added (ppm) and the installation size are specified in this menu.
The installation cuts out below the min. volume of water (installation capacity
< 2.5%).
●
Press "Enter" to confirm
Display indicator:
Contact input
activated
●
Press "Enter" to go back to the "Mode" menu
●
Press "Escape" 2x to go back to the main menu
NOTE
Preset water flowrate at the contact and current input in
m³/h. Can also be selected by pressing "F1": l/s;%
Basic load setting
Display indicator:
Contact input <
0 g/h = 0.00 pulses/sec.
9 g/h = 8.33 pulses/sec.
Press "F1" to switch to the variable field 0 g/h and to set a basic load.
NOTE
Basic load > 2.5% of the installation capacity, e.g. 164-10D;
basic load > 0.25 g/h