background image

6

CONTENTS

Page

1.

Symbols used in this document

6

2.

Product description

7

2.1

Indicator lights

7

2.2

Terminals

7

2.3

Potentially explosive environments

8

3.

Identification

8

3.1

Type key

8

4.

Installation

8

4.1

Location

9

4.2

Enclosure class

9

4.3

Terminals

9

4.4

Cables

9

5.

Mechanical installation

9

6.

EMC-correct installation

10

6.1

Internal GENIbus connection to the
IO 351 and IO 111

11

6.2

Fieldbus communication interface 
modules

11

6.3

Fitting the CIM module

11

7.

Start-up

13

8.

Technical data

13

9.

Electrical data

13

9.1

Supply voltage

13

9.2

Power consumption

13

9.3

Circuit breaker

13

9.4

Digital inputs

13

9.5

Analog inputs

13

9.6

Digital outputs (relay outputs)

13

9.7

Conductors

13

9.8

Battery backup (UPS)

14

9.9

Terminal groups

14

10.

Overview of inputs and outputs

15

11.

Maintenance

16

12.

Service

16

13.

Replacing the CU 361

16

13.1 Replacing the CIM module

16

14.

Dimensions

16

15.

Disposal

16

1. Symbols used in this document

Warning

Prior to installation, read these 
installation and operating instructions. 
Installation and operation must comply 
with local regulations and accepted 
codes of good practice.

Warning

If these safety instructions are not 
observed, it may result in personal 
injury!

Caution

If these safety instructions are not 
observed, it may result in malfunction 
or damage to the equipment!

Note

Notes or instructions that make the job 
easier and ensure safe operation. 

Summary of Contents for CU 361

Page 1: ...4 Digital inputs 13 9 5 Analog inputs 13 9 6 Digital outputs relay outputs 13 9 7 Conductors 13 9 8 Battery backup UPS 14 9 9 Terminal groups 14 10 Overview of inputs and outputs 15 11 Maintenance 16...

Page 2: ...Description 1 LCD display 2 Changes to next column in menu structure 3 Changes to help text 4 Goes up in lists 5 Goes down in lists 6 Increases the value of a selected parameter 7 Reduces the value of...

Page 3: ...ear week 5 Rated voltage frequency and power TM04 2367 2408 TM00 5827 3408 Type Made in Thailand 96161750 Product No UN Serial No P c OPEN TYPE PROCESS CONTROL EQUIPMENT 100 240 Vac 50 60Hz Max 22W CU...

Page 4: ...ating 1 2 3 3R 5 12 12K or 13 4 3 Terminals All terminals are suitable for conductors of 0 5 to 2 5 mm2 or AWG 20 13 4 4 Cables Cables must be rated min 70 C 5 Mechanical installation Fasten the CU 36...

Page 5: ...e CIM module Fig 8 Screen fixed with cable clamp Signal conductors for digital and analog inputs and outputs should be screened i e run the screen all the way to the CU 361 and connect it to frame wit...

Page 6: ...s will be available in the future The CIM modules must be ordered separately The connection of the CIM module is described in the installation and operating instructions supplied with the module 6 3 F...

Page 7: ...upplied with the CIM module on the back cover See fig 13 Fig 13 Placing the new labels on the back cover 5 Refit the back cover to the CU 361 and secure it with the mounting screw See fig 14 Fig 14 Re...

Page 8: ...rcuit breakers must be done in accordance with local and national regulations 9 4 Digital inputs 9 5 Analog inputs 9 6 Digital outputs relay outputs 9 7 Conductors Warning Prior to start up read the i...

Page 9: ...e terminals of the groups 2 3 5 and 6 are insulated from all other terminal groups by reinforced insulation 2224 VAC All control terminals in groups 2 3 5 and 6 are supplied with SELV voltage Safety E...

Page 10: ...ut 11 GND 12 DI2 13 GND 14 DI3 All terminals except mains terminals must only be connected to voltages not exceeding 16 Vrms and 22 6 Vpeak or 35 VDC 6 Ethernet RJ45 External computing devices connect...

Page 11: ...ff the power supply to the CU 361 2 Switch off the power supply to components with external supply 3 Mark the individual conductors with the numbers of the corresponding terminals 4 Remove the screws...

Reviews: